Abstract
Eye movement artifacts occurring during 3-D optical coherence tomography (OCT) scanning is a well-recognized problem that may adversely affect image analysis and interpretation. A particle filtering algorithm is presented in this paper to correct motion in a 3-D dataset by considering eye movement as a target tracking problem in a dynamic system. The proposed particle filtering algorithm is an independent 3-D alignment approach, which does not rely on any reference image. 3-D OCT data is considered as a dynamic system, while the location of each A-scan is represented by the state space. A particle set is used to approximate the probability density of the state in the dynamic system. The state of the system is updated frame by frame to detect A-scan movement. The proposed method was applied on both simulated data for objective evaluation and experimental data for subjective evaluation. The sensitivity and specificity of the x-movement detection were 98.85% and 99.43%, respectively, in the simulated data. For the experimental data (74 3-D OCT images), all the images were improved after z-alignment, while 81.1% images were improved after x-alignment. The proposed algorithm is an efficient way to align 3-D OCT volume data and correct the eye movement without using references.
| Original language | English (US) |
|---|---|
| Article number | 6122510 |
| Pages (from-to) | 1337-1345 |
| Number of pages | 9 |
| Journal | IEEE Transactions on Medical Imaging |
| Volume | 31 |
| Issue number | 7 |
| DOIs | |
| State | Published - 2012 |
| Externally published | Yes |
Funding
Manuscript received November 10, 2011; revised December 22, 2011; accepted December 22, 2011. Date of publication January 04, 2012; date of current version June 26, 2012. This work was supported in part by the National Institutes of Health (NIH) under Grant NIH R01-EY013178 and Grant P30-EY008098, in part by the Eye and Ear Foundation (Pittsburgh, PA), and in part by Research to Prevent Blindness. Asterisk indicates corresponding author. *J. Xu is with the Department of Ophthalmology, UPMC Eye Center, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213 USA (e-mail: [email protected]).
| Funders | Funder number |
|---|---|
| Eye and Ear Foundation | |
| Author National Institutes of Health National Institutes of Health National Institutes of Health National Institutes of Health The Bev Hartig Huntington's Disease Foundation National Institutes of Health | R01-EY013178 |
| National Eye Institute and Casey Eye Institute | P30EY008098 |
| Research to Prevent Blindness |
Keywords
- Eye movement correction
- particle filtering
- retinal image processing
- three-dimensional optical coherence tomography (3-D OCT)
ASJC Scopus subject areas
- Software
- Radiological and Ultrasound Technology
- Computer Science Applications
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS