Skip to main navigation Skip to search Skip to main content

Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering

Research output: Contribution to journal › Article › peer-review

Abstract

Eye movement artifacts occurring during 3-D optical coherence tomography (OCT) scanning is a well-recognized problem that may adversely affect image analysis and interpretation. A particle filtering algorithm is presented in this paper to correct motion in a 3-D dataset by considering eye movement as a target tracking problem in a dynamic system. The proposed particle filtering algorithm is an independent 3-D alignment approach, which does not rely on any reference image. 3-D OCT data is considered as a dynamic system, while the location of each A-scan is represented by the state space. A particle set is used to approximate the probability density of the state in the dynamic system. The state of the system is updated frame by frame to detect A-scan movement. The proposed method was applied on both simulated data for objective evaluation and experimental data for subjective evaluation. The sensitivity and specificity of the x-movement detection were 98.85% and 99.43%, respectively, in the simulated data. For the experimental data (74 3-D OCT images), all the images were improved after z-alignment, while 81.1% images were improved after x-alignment. The proposed algorithm is an efficient way to align 3-D OCT volume data and correct the eye movement without using references.

Original languageEnglish (US)
Article number6122510
Pages (from-to)1337-1345
Number of pages9
JournalIEEE Transactions on Medical Imaging
Volume31
Issue number7
DOIs
StatePublished - 2012
Externally publishedYes

Funding

Manuscript received November 10, 2011; revised December 22, 2011; accepted December 22, 2011. Date of publication January 04, 2012; date of current version June 26, 2012. This work was supported in part by the National Institutes of Health (NIH) under Grant NIH R01-EY013178 and Grant P30-EY008098, in part by the Eye and Ear Foundation (Pittsburgh, PA), and in part by Research to Prevent Blindness. Asterisk indicates corresponding author. *J. Xu is with the Department of Ophthalmology, UPMC Eye Center, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213 USA (e-mail: [email protected]).

FundersFunder number
Eye and Ear Foundation
Author National Institutes of Health National Institutes of Health National Institutes of Health National Institutes of Health The Bev Hartig Huntington's Disease Foundation National Institutes of HealthR01-EY013178
National Eye Institute and Casey Eye InstituteP30EY008098
Research to Prevent Blindness

    Keywords

    • Eye movement correction
    • particle filtering
    • retinal image processing
    • three-dimensional optical coherence tomography (3-D OCT)

    ASJC Scopus subject areas

    • Software
    • Radiological and Ultrasound Technology
    • Computer Science Applications
    • Electrical and Electronic Engineering

    Fingerprint

    Dive into the research topics of 'Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering'. Together they form a unique fingerprint.

    Cite this