TY - JOUR
T1 - Clinical Performance of CAD/CAM Monolithic Lithium Disilicate Implant-Supported Single Crowns Using Solid or Predrilled Blocks in a Fully Digital Workflow
T2 - A Retrospective Cohort Study With Up To 33 Months of Follow Up
AU - Bompolaki, Despoina
AU - Punj, Amit
AU - Fellows, Christopher
AU - Truong, Christina
AU - Ferracane, Jack L.
N1 - Publisher Copyright:
© 2021 by the American College of Prosthodontists
PY - 2022/1
Y1 - 2022/1
N2 - Purpose: To assess the clinical performance of CAD/CAM monolithic implant-supported restorations manufactured using a fully digital workflow and two different types of ceramic blocks. Materials and Methods: One hundred and one patients received single-unit implant-supported restorations at a University predoctoral clinic. All restorations were designed and fabricated using either a predrilled LS2 block (group P, n = 59) or a conventional solid LS2 block with an occlusal opening drilled manually prior to crystallization (group M, n = 42). The mean follow-up time after restoration delivery was 18.4 ± 4.8 months (range 12 to 33 months). Patients with less than a 12-month follow-up were excluded. Electronic health records were reviewed to identify number and type of complications during the follow-up time. Clinical outcomes were classified as success, survival, and failure of the restoration. Chi-square tests were used to identify differences in success and survival rates between the groups. Nonparametric Mann-Whitney U tests were used to identify differences in the number of major and minor complications as well as the total number of complications that were observed among groups. Results: Overall success and survival rates were 80.2% and 97%, respectively. Seventy one restorations (70.3%) were complication-free. There were no significant differences between the groups with regards to the number of complications or success and survival rates. Conclusions: Single-unit CAD/CAM monolithic implant-supported restorations that are fabricated in a fully digital workflow present relatively high complication rates and moderate short-term clinical outcomes. Clinical studies with longer follow-up times are needed to evaluate long-term outcomes of these restorations.
AB - Purpose: To assess the clinical performance of CAD/CAM monolithic implant-supported restorations manufactured using a fully digital workflow and two different types of ceramic blocks. Materials and Methods: One hundred and one patients received single-unit implant-supported restorations at a University predoctoral clinic. All restorations were designed and fabricated using either a predrilled LS2 block (group P, n = 59) or a conventional solid LS2 block with an occlusal opening drilled manually prior to crystallization (group M, n = 42). The mean follow-up time after restoration delivery was 18.4 ± 4.8 months (range 12 to 33 months). Patients with less than a 12-month follow-up were excluded. Electronic health records were reviewed to identify number and type of complications during the follow-up time. Clinical outcomes were classified as success, survival, and failure of the restoration. Chi-square tests were used to identify differences in success and survival rates between the groups. Nonparametric Mann-Whitney U tests were used to identify differences in the number of major and minor complications as well as the total number of complications that were observed among groups. Results: Overall success and survival rates were 80.2% and 97%, respectively. Seventy one restorations (70.3%) were complication-free. There were no significant differences between the groups with regards to the number of complications or success and survival rates. Conclusions: Single-unit CAD/CAM monolithic implant-supported restorations that are fabricated in a fully digital workflow present relatively high complication rates and moderate short-term clinical outcomes. Clinical studies with longer follow-up times are needed to evaluate long-term outcomes of these restorations.
UR - http://www.scopus.com/inward/record.url?scp=85122714199&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85122714199&partnerID=8YFLogxK
U2 - 10.1111/jopr.13364
DO - 10.1111/jopr.13364
M3 - Article
C2 - 33840144
AN - SCOPUS:85122714199
SN - 1059-941X
VL - 31
SP - 38
EP - 44
JO - Journal of Prosthodontics
JF - Journal of Prosthodontics
IS - 1
ER -