TY - JOUR
T1 - Confocal fluorescence microscopy platform suitable for rapid evaluation of small fragments of tissue in surgical pathology practice
AU - Krishnamurthy, Savitri
AU - Ban, Kechen
AU - Shaw, Kenna
AU - Mills, Gordon
AU - Sheth, Rahul
AU - Tam, Alda
AU - Gupta, Sanjay
AU - Sabir, Sharjeel
N1 - Publisher Copyright:
© 2019 DIOmed Verlags GmbH. All rights reserved.
PY - 2019/3
Y1 - 2019/3
N2 - Context.-Rapid advances in the fields of biophotonics, computer science, and instrumentation have allowed for high-resolution imaging of biologic tissues. Objective.-To evaluate the quality of images from an optimized confocal fluorescence microscopy (CFM) platform for rapid evaluation of small fragments of tissue, compared with hematoxylin-eosin staining. Design.-Tissue fragments (up to 1.0 × 0.3 cm) were stained with 0.6 mM acridine orange for 60 seconds and imaged using a CFM platform at 488-nm and 785-nm wavelength. The imaged tissues were then fixed in formalin and processed to generate hematoxylin-eosin-stained tissue sections. The quality of CFM images was scored on a scale of 0 to 3 on the basis of the percentage of the CFM images with recognizable tissue architecture (0, 0%; 1, <20%; 2, 20%-50%; 3, >50%). The diagnoses made using CFM images were compared with those made using histopathologic analysis of the hematoxylin-eosin-stained tissue sections. Results.-We imaged 118 tissue fragments obtained from 40 breast, 23 lung, 39 kidney, and 16 liver surgical excision specimens. We acquired CFM images in 2 to 3 minutes; 95.8% (113 of 118) of images showed a quality score of 3, and 4.2% (5 of 118) had a score of 2. We achieved a sensitivity of 95.5%, specificity of 97.3%, positive predictive value of 95.5%, and negative predictive value of 97.3%. Conclusions.-Our results demonstrate the suitability of the CFM platform for rapid and accurate evaluation of small tissue fragments in surgical pathology practice.
AB - Context.-Rapid advances in the fields of biophotonics, computer science, and instrumentation have allowed for high-resolution imaging of biologic tissues. Objective.-To evaluate the quality of images from an optimized confocal fluorescence microscopy (CFM) platform for rapid evaluation of small fragments of tissue, compared with hematoxylin-eosin staining. Design.-Tissue fragments (up to 1.0 × 0.3 cm) were stained with 0.6 mM acridine orange for 60 seconds and imaged using a CFM platform at 488-nm and 785-nm wavelength. The imaged tissues were then fixed in formalin and processed to generate hematoxylin-eosin-stained tissue sections. The quality of CFM images was scored on a scale of 0 to 3 on the basis of the percentage of the CFM images with recognizable tissue architecture (0, 0%; 1, <20%; 2, 20%-50%; 3, >50%). The diagnoses made using CFM images were compared with those made using histopathologic analysis of the hematoxylin-eosin-stained tissue sections. Results.-We imaged 118 tissue fragments obtained from 40 breast, 23 lung, 39 kidney, and 16 liver surgical excision specimens. We acquired CFM images in 2 to 3 minutes; 95.8% (113 of 118) of images showed a quality score of 3, and 4.2% (5 of 118) had a score of 2. We achieved a sensitivity of 95.5%, specificity of 97.3%, positive predictive value of 95.5%, and negative predictive value of 97.3%. Conclusions.-Our results demonstrate the suitability of the CFM platform for rapid and accurate evaluation of small tissue fragments in surgical pathology practice.
UR - http://www.scopus.com/inward/record.url?scp=85062282782&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85062282782&partnerID=8YFLogxK
U2 - 10.5858/arpa.2018-0352-OA
DO - 10.5858/arpa.2018-0352-OA
M3 - Article
C2 - 30376375
AN - SCOPUS:85062282782
SN - 0003-9985
VL - 143
SP - 305
EP - 313
JO - Archives of Pathology and Laboratory Medicine
JF - Archives of Pathology and Laboratory Medicine
IS - 3
ER -