TY - JOUR
T1 - Construct validity of patient-reported outcome instruments in US adults with hemophilia
T2 - Results from the pain, functional impairment, and quality of life (P-FiQ) study
AU - Batt, Katharine
AU - Recht, Michael
AU - Cooper, David L.
AU - Iyer, Neeraj N.
AU - Kempton, Christine L.
N1 - Funding Information:
The P-FiQ study was managed by Quintiles Real World and Late Phase, Boston, Massachusetts, and Rockville, Maryland, with statistical analyses provided by Jennifer James, Senior Biostatistician, and was supported financially by Novo Nordisk Inc. Writing assistance was provided by Anna Abt, PhD, of ETHOS Health Communications, Yardley,
Publisher Copyright:
© 2017 Batt et al.
PY - 2017/8/9
Y1 - 2017/8/9
N2 - Background: People with hemophilia (PWH) experience frequent joint bleeding, resulting in pain and functional impairment. Generic and disease-specific patient-reported outcome (PRO) instruments have been used in clinical studies, but rarely in the comprehensive hemophilia care setting. Objective: The objective of this study was to assess construct validity of PRO instruments measuring pain, functional impairment, and health-related quality of life in US PWH with a history of joint pain/bleeding. Methods: Adult male PWH completed 4 PRO instruments (EQ-5D-5L with visual analog scale, Brief Pain Inventory v2 Short Form [BPI], SF-36v2, Hemophilia Activities List [HAL]) and underwent a musculoskeletal examination (Hemophilia Joint Health Score v2.1 [HJHS]). Construct validity between index and domain scores was evaluated by Pearson product-moment correlation coefficient. Results: A total of 381 PWH were enrolled. EQ-5D-5L Mobility correlated with BPI, SF-36v2, and HAL domains related to pain, physical function, and activity of the lower extremities. EQ-5D-5L Self-Care correlated only with HAL Self-Care. EQ-5D-5L Usual Activities correlated with BPI Pain Interference and domains within SF-36v2 and HAL related to pain and physical function/ activities (particularly those involving the lower extremities). EQ-5D-5L Pain/Discomfort correlated with Bodily Pain and Physical Summary on SF-36v2, HAL Overall Activity, and all BPI pain domains. EQ-5D-5L Anxiety/Depression correlated with social/emotional/mental aspects of SF-36v2. On BPI, most pain domains correlated with Bodily Pain and Physical Health Summary on SF-36v2 and Overall Activity on HAL. On SF-36v2, Physical Functioning, Role Physical, Bodily Pain, and Physical Health summary scores correlated with all the domains of HAL except Self-Care. For HJHS, Ankle and Total scores correlated with SF-36v2 Physical Functioning and HAL Lying/Sitting, Leg Function, Complex Lower Extremity Activity, and Overall Activity. Conclusion: All PRO instruments have high construct validity but provide different levels of detail in describing effects of hemophilia. Instrument choice may depend on individuals’ symptoms, treatment planning goals, or outcome tracking research objectives, with consideration for administrative burden.
AB - Background: People with hemophilia (PWH) experience frequent joint bleeding, resulting in pain and functional impairment. Generic and disease-specific patient-reported outcome (PRO) instruments have been used in clinical studies, but rarely in the comprehensive hemophilia care setting. Objective: The objective of this study was to assess construct validity of PRO instruments measuring pain, functional impairment, and health-related quality of life in US PWH with a history of joint pain/bleeding. Methods: Adult male PWH completed 4 PRO instruments (EQ-5D-5L with visual analog scale, Brief Pain Inventory v2 Short Form [BPI], SF-36v2, Hemophilia Activities List [HAL]) and underwent a musculoskeletal examination (Hemophilia Joint Health Score v2.1 [HJHS]). Construct validity between index and domain scores was evaluated by Pearson product-moment correlation coefficient. Results: A total of 381 PWH were enrolled. EQ-5D-5L Mobility correlated with BPI, SF-36v2, and HAL domains related to pain, physical function, and activity of the lower extremities. EQ-5D-5L Self-Care correlated only with HAL Self-Care. EQ-5D-5L Usual Activities correlated with BPI Pain Interference and domains within SF-36v2 and HAL related to pain and physical function/ activities (particularly those involving the lower extremities). EQ-5D-5L Pain/Discomfort correlated with Bodily Pain and Physical Summary on SF-36v2, HAL Overall Activity, and all BPI pain domains. EQ-5D-5L Anxiety/Depression correlated with social/emotional/mental aspects of SF-36v2. On BPI, most pain domains correlated with Bodily Pain and Physical Health Summary on SF-36v2 and Overall Activity on HAL. On SF-36v2, Physical Functioning, Role Physical, Bodily Pain, and Physical Health summary scores correlated with all the domains of HAL except Self-Care. For HJHS, Ankle and Total scores correlated with SF-36v2 Physical Functioning and HAL Lying/Sitting, Leg Function, Complex Lower Extremity Activity, and Overall Activity. Conclusion: All PRO instruments have high construct validity but provide different levels of detail in describing effects of hemophilia. Instrument choice may depend on individuals’ symptoms, treatment planning goals, or outcome tracking research objectives, with consideration for administrative burden.
KW - Construct validity
KW - Functional impairment
KW - Hemophilia
KW - Pain
KW - Patient-reported outcomes
KW - Quality of life
UR - http://www.scopus.com/inward/record.url?scp=85027883290&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85027883290&partnerID=8YFLogxK
U2 - 10.2147/PPA.S141390
DO - 10.2147/PPA.S141390
M3 - Article
AN - SCOPUS:85027883290
SN - 1177-889X
VL - 11
SP - 1369
EP - 1380
JO - Patient Preference and Adherence
JF - Patient Preference and Adherence
ER -