Cyclic variation in ultrasonic myocardial integrated backscatter is due to phasic changes in the number of patent myocardial microvessels

Antonio Micari, Marco Pascotto, Ananda R. Jayaweera, Jiri Sklenar, N. Craig Goodman, Sanjiv Kaul

Research output: Contribution to journalArticlepeer-review

12 Scopus citations

Abstract

Objective. We tested the hypothesis that the cyclic variation in ultrasonic myocardial integrated backscatter (IBS) is due to cardiac contraction-induced changes in the number of patent myocardial microvessels. Methods. We performed experiments in open-chest dogs in which we increased the number of patent myocardial microvessels without changing cardiac contraction. We achieved this either by direct intracoronary administration of adenosine (group 1; n = 10) or by producing a noncritical coronary stenosis (group 2; n = 7). Results. At baseline, IBS was lowest in systole and highest in diastole. This cyclic variation in IBS was closely associated with the phasic changes in myocardial blood volume that were measured with myocardial contrast echocardiography During adenosine administration, the diastolic IBS increased from -18.8 ± 6.5 to -17.5 ± 6.1 dB (P = .002), with an associated increase in the difference between the systolic and diastolic IBS from 3.8 ± 1.1 to 4.6 ± 1.0 dB (P = .009). After a non-critical stenosis was produced, diastolic IBS also increased from -26.6 ± 8.3 to -25.2 ±7.3 dB (P = .001), with an associated increase in the difference between the systolic and diastolic IBS from 3.7 ± 1.2 to 5.0 ± 1.0 dB (P = .02). No change in IBS was noted in the bed that did not receive adenosine or the bed that had a stenosis. Conclusions. The variation in IBS during the cardiac cycle is closely associated with the phasic changes in myocardial blood volume seen during cardiac contraction. When the number of patent myocardial arterioles is increased via adenosine or placement of a noncritical stenosis, diastolic IBS increases with a concomitant increase in IBS cyclic variation. These results may have important clinical applications for the noninvasive diagnosis of noncritical coronary stenosis at rest.

Original languageEnglish (US)
Pages (from-to)1009-1019
Number of pages11
JournalJournal of Ultrasound in Medicine
Volume25
Issue number8
DOIs
StatePublished - Aug 2006

Keywords

  • Cardiac contraction
  • Cyclic variation
  • Integrated backscatter
  • Myocardial blood volume

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Cyclic variation in ultrasonic myocardial integrated backscatter is due to phasic changes in the number of patent myocardial microvessels'. Together they form a unique fingerprint.

Cite this