Skip to main navigation Skip to search Skip to main content

Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry

  • Thomas A. Dewland
  • , Cara N. Pellegrini
  • , Yongfei Wang
  • , Gregory M. Marcus
  • , Edmund Keung
  • , Paul D. Varosy

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: The aim of this study was to compare single- versus dual-chamber implantable cardioverter-defibrillator (ICD) implantation and complication rates in a large, real-world population. Background: The majority of patients enrolled in ICD efficacy trials received single-chamber devices. Although dual-chamber ICDs offer theoretical advantages over single-chamber defibrillators, the clinical superiority of dual-chamber models has not been conclusively proven, and they may increase complications. Methods: The National Cardiovascular Data Registry ICD Registry was used to examine the association between baseline characteristics and device selection in 104,049 patients receiving single- and dual-chamber ICDs between January 1, 2006, and December 31, 2007. A longitudinal cohort design was then used to determine in-hospital complication rates. Results: Dual-chamber devices were implanted in 64,489 patients (62%). Adverse events were more frequent with dual-chamber than with single-chamber device implantation (3.17% vs. 2.11%, p < 0.001), as was the rate of in-hospital mortality (0.40% vs. 0.23%, p < 0.001). After adjusting for demographics, medical comorbidities, diagnostic test data, and ICD indication, the odds of any complication (odds ratio: 1.40; 95% confidence interval: 1.28 to 1.52; p < 0.001) and in-hospital mortality (odds ratio: 1.45; 95% confidence interval: 1.20 to 1.74; p < 0.001) were increased with dual-chamber versus single-chamber ICD implantation. Conclusions: In this large, multicenter cohort of patients, dual-chamber ICD use was common. Dual-chamber device implantation was associated with increases in periprocedural complications and in-hospital mortality compared with single-chamber defibrillator selection.

Original languageEnglish (US)
Pages (from-to)1007-1013
Number of pages7
JournalJournal of the American College of Cardiology
Volume58
Issue number10
DOIs
StatePublished - Aug 30 2011
Externally publishedYes

Funding

Funding for this study was provided in part by a Research Career Development Award (RCD 04-115-2 to Dr. Varosy) from the Veterans Administration Office of Health Services Research and Development. Dr. Marcus has received research funding from St. Jude Medical and speaker's fees from Biotronik and St. Jude Medical. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.

Funders
St. Jude Medical
Office of Research and Development Clinical Research and Development Program
BIOTRONIK

    Keywords

    • complication
    • defibrillator
    • dual-chamber ICD

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine

    Fingerprint

    Dive into the research topics of 'Dual-chamber implantable cardioverter-defibrillator selection is associated with increased complication rates and mortality among patients enrolled in the NCDR implantable cardioverter-defibrillator registry'. Together they form a unique fingerprint.

    Cite this