T1 - Efficacy of the Abdominal Aortic Junctional Tourniquet-Torso Plate in a Lethal Model of Noncompressible Torso Hemorrhage
AU - Bonanno, Alicia Marie
AU - Hoops, Heather E.
AU - Graham, Todd
AU - Davis, Benjamin L.
AU - McCully, Belinda H.
AU - Wilson, Lauren N.
AU - Madtson, Brianne M.
AU - Ross, James
N1 - Publisher Copyright:
2018.
PY - 2018/12/1
Y1 - 2018/12/1
N2 - BACKGROUND: The Abdominal Aortic Junctional Tourniquet, when modified with an off-label, prototype, accessory pressure distribution plate (AAJT-TP), has the potential to control noncompressible torso hemorrhage in prolonged field care. METHODS: Using a lethal, noncompressible torso hemorrhage model, 24 male Yorkshire swine (81kg-96kg) were randomly assigned into two groups (control or AAJT-TP). Anesthetized animals were instrumented and an 80% laparoscopic, left-side liver lobe transection was performed. At 10 minutes, the AAJT-TP was applied and inflated to an intraabdominal pressure of 40mmHg. At 20 minutes after application, the AAJT-TP was deflated, but the windlass was left tightened. Animals were observed for a prehospital time of 60 minutes. Animals then underwent damage control surgery at 180 minutes, followed by an intensive care unit-phase of care for an additional 240 minutes. Survival was the primary end point. RESULTS: Compared with Hextend, survival was not significantly different in the AAJT-TP group (ρ = .564), nor was blood loss (3.3L ± 0.5L and 3.0L ± 0.5L, respectively; p = .285). There was also no difference in all physiologic parameters between groups at the end of the study or end of the prehospital phase. Three of 12 AAJT-TP animals had an inferior vena cava thrombus. CONCLUSION: The AAJT-TP did not provide any survival benefit compared with Hextend alone in this model of noncompressible torso hemorrhage.
AB - BACKGROUND: The Abdominal Aortic Junctional Tourniquet, when modified with an off-label, prototype, accessory pressure distribution plate (AAJT-TP), has the potential to control noncompressible torso hemorrhage in prolonged field care. METHODS: Using a lethal, noncompressible torso hemorrhage model, 24 male Yorkshire swine (81kg-96kg) were randomly assigned into two groups (control or AAJT-TP). Anesthetized animals were instrumented and an 80% laparoscopic, left-side liver lobe transection was performed. At 10 minutes, the AAJT-TP was applied and inflated to an intraabdominal pressure of 40mmHg. At 20 minutes after application, the AAJT-TP was deflated, but the windlass was left tightened. Animals were observed for a prehospital time of 60 minutes. Animals then underwent damage control surgery at 180 minutes, followed by an intensive care unit-phase of care for an additional 240 minutes. Survival was the primary end point. RESULTS: Compared with Hextend, survival was not significantly different in the AAJT-TP group (ρ = .564), nor was blood loss (3.3L ± 0.5L and 3.0L ± 0.5L, respectively; p = .285). There was also no difference in all physiologic parameters between groups at the end of the study or end of the prehospital phase. Three of 12 AAJT-TP animals had an inferior vena cava thrombus. CONCLUSION: The AAJT-TP did not provide any survival benefit compared with Hextend alone in this model of noncompressible torso hemorrhage.
UR - http://www.scopus.com/inward/record.url?scp=85058880262&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85058880262&partnerID=8YFLogxK
M3 - Article
C2 - 30566733
AN - SCOPUS:85058880262
SN - 1553-9768
VL - 18
SP - 106
EP - 110
JO - Journal of special operations medicine : a peer reviewed journal for SOF medical professionals
JF - Journal of special operations medicine : a peer reviewed journal for SOF medical professionals
IS - 4
ER -