TY - JOUR
T1 - Evaluation of diamond-coated ultrasonic instruments for root-end preparation
AU - Brent, Paul D.
AU - Morgan, Leslie A.
AU - Marshall, J. Gordon
AU - Baumgartner, John (Craig)
PY - 1999/10
Y1 - 1999/10
N2 - Ultrasonic instrumentation has been associated with cracking of the dentin in the area of the root-end preparation. The purpose of this study was to evaluate root-end preparations for cracking and to describe cavosurface morphology after the use of diamond-coated instruments. Forty teeth were inspected for intradentin cracks, incomplete canal cracks, and complete canal cracks before and after preparation with a stainless steel CT-5 ultrasonic instrument and again after root-end preparation with an S12D/90° diamond-coated instru-ment. Six teeth had polyvinylsiloxane impressions taken of the root ends after preparation with the CT-5 and again after preparation with the diamond-coated instrument. Replicas were made, split, sputter-coated, and inspected using the scanning electron microscope. This study indicates that use of the diamond-coated instrument for root-end preparation does not result in significant root-end cracking and that it can remove cracks created by a prior instrument's use. The use of the diamond-coated instrument resulted in a heavily abraded, debris-covered cavosurface that may affect the apical seal.
AB - Ultrasonic instrumentation has been associated with cracking of the dentin in the area of the root-end preparation. The purpose of this study was to evaluate root-end preparations for cracking and to describe cavosurface morphology after the use of diamond-coated instruments. Forty teeth were inspected for intradentin cracks, incomplete canal cracks, and complete canal cracks before and after preparation with a stainless steel CT-5 ultrasonic instrument and again after root-end preparation with an S12D/90° diamond-coated instru-ment. Six teeth had polyvinylsiloxane impressions taken of the root ends after preparation with the CT-5 and again after preparation with the diamond-coated instrument. Replicas were made, split, sputter-coated, and inspected using the scanning electron microscope. This study indicates that use of the diamond-coated instrument for root-end preparation does not result in significant root-end cracking and that it can remove cracks created by a prior instrument's use. The use of the diamond-coated instrument resulted in a heavily abraded, debris-covered cavosurface that may affect the apical seal.
UR - http://www.scopus.com/inward/record.url?scp=0033202842&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033202842&partnerID=8YFLogxK
U2 - 10.1016/S0099-2399(99)80353-7
DO - 10.1016/S0099-2399(99)80353-7
M3 - Article
C2 - 10687526
AN - SCOPUS:0033202842
SN - 0099-2399
VL - 25
SP - 672
EP - 675
JO - Journal of Endodontics
JF - Journal of Endodontics
IS - 10
ER -