Skip to main navigation Skip to search Skip to main content

In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging

  • Shiva Sharma
  • , Ann E. Ensley
  • , Katharine Hopkins
  • , George P. Chatzimavroudis
  • , Timothy M. Healy
  • , Vincent K.H. Tam
  • , Kirk R. Kanter
  • , Ajit P. Yoganathan

Research output: Contribution to journalArticlepeer-review

Abstract

Background. The total cavopulmonary connection (TCPC) design continues to be refined on the basis of flow analysis at the connection site. These refinements are of importance for myocardial energy conservation in the univentricular supported circulation. In vivo magnetic resonance phase contrast imaging provides semiquantitative flow visualization information. The purpose of this study was to understand the in vivo TCPC flow characteristics obtained by magnetic resonance phase contrast imaging and compare the results with our previous in vitro TCPC flow experiments in an effort to further refine TCPC surgical design. Methods. Twelve patients with TCPC underwent sedated three-dimensional, multislice magnetic resonance phase contrast imaging. Seven patients had intraatrial lateral tunnel TCPC and 5 had extracardiac TCPC. Results. In all patients in both groups a disordered flow pattern was observed in the inferior caval portion of the TCPC. Flow at the TCPC site appeared to be determined by connection geometry, being streamlined at the superior vena cava-pulmonary junction when the superior vena cava was offset and flared toward the left pulmonary artery. Without caval offset, intense swirling and dominance of superior vena caval flow was observed. In TCPC with bilateral superior vena cavae, the flow patterns observed included secondary vortices, a central stagnation point, and influx of the superior vena cava flow into the inferior caval conduit. A comparative analysis of in vivo flow and our previous in vitro flow data from glass model prototypes of TCPC demonstrated significant similarities in flow disturbances. Three-dimensional magnetic resonance phase contrast imaging in multiple Coronal planes enabled a comprehensive semiquantitative flow analysis. The data are presented in traditional instantaneous images and in animated format for interactive display of the flow dynamics. Conclusions. Flow in the inferior caval portion of the TCPC is disordered, and the TCPC geometry determines flow characteristics.

Original languageEnglish (US)
Pages (from-to)889-898
Number of pages10
JournalAnnals of Thoracic Surgery
Volume71
Issue number3
DOIs
StatePublished - 2001
Externally publishedYes

Funding

From 20 patients who underwent magnetic resonance scans, 12 patients had complete studies and form the study group. In 8 of 20 patients, studies were excluded for movement artifact due to patient awakening [3] , artifact from coils in systemic pulmonary collaterals [1] , insufficient scan time [3] , and a technical masking error [1] . The study protocol was approved by the Institutional Review Board of Emory University School of Medicine and informed consent was obtained from parents. The studies were fully funded by American Heart Association (Georgia Affiliate) Grant for the study period from July 1996 to July 1999.

Funders
American Heart Association/American Stroke Association

    ASJC Scopus subject areas

    • Surgery
    • Pulmonary and Respiratory Medicine
    • Cardiology and Cardiovascular Medicine

    Fingerprint

    Dive into the research topics of 'In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging'. Together they form a unique fingerprint.

    Cite this