Skip to main navigation Skip to search Skip to main content

Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation

  • Aamir Cheema
  • , Jun Dong
  • , Darshan Dalal
  • , Chandrasekhar R. Vasamreddy
  • , Joseph E. Marine
  • , Charles A. Henrikson
  • , David Spragg
  • , Alan Cheng
  • , Saman Nazarian
  • , Sunil Sinha
  • , Henry Halperin
  • , Ronald Berger
  • , Hugh Calkins

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Each of the two main approaches to catheter ablation of atrial fibrillation (AF, segmental and circumferential) is associated with moderate long-term efficacy. Objective: To report the long-term outcomes of a modified technique that combines circumferential ablation with pulmonary vein (PV) isolation, determined by a circular mapping catheter and to determine the relationship between complete PV isolation and long-term efficacy. Methods: The patient population was composed of 64 consecutive patients (47 men [73%]; age 59 ± 11 years) with AF who underwent catheter ablation. AF was paroxysmal in 29 (45%) and nonparoxysmal in 35 (55%). Each patient was followed for a minimum of 12 months. Results: After a mean follow-up of 13 ± 1 months, the long-term single-procedure success rate was 45% (n = 29) with an additional 4% (n = 3) of patients demonstrating improvement. With repeat procedures in 19 patients, the overall long-term success rate was 62% (n = 40) with 9% (n = 6) demonstrating improvement. All the patients who underwent repeat ablations had recovered PV conduction. Incomplete PV isolation was the only independent predictor of failure. A major complication occurred in four (6%) patients, including three patients with vascular complications and one with cardiac tamponade. Conclusion: Our results suggest that the long-term single-procedure efficacy of circumferential ablation with PV isolation in a cohort of patients with predominantly nonparoxysmal AF approaches 50%. Repeat procedures involving re-isolation of the PVs result in a significant improvement in outcomes. Complete electrical isolation of the PVs has a significant impact on the long-term efficacy of the procedure.

Original languageEnglish (US)
Pages (from-to)1080-1085
Number of pages6
JournalJournal of cardiovascular electrophysiology
Volume17
Issue number10
DOIs
StatePublished - Oct 2006
Externally publishedYes

Funding

FundersFunder number
National Institute of Health National Heart, Lung, and Blood InstituteR01HL064795

    Keywords

    • Atrial fibrillation
    • Catheter ablation
    • Pulmonary vein

    ASJC Scopus subject areas

    • Cardiology and Cardiovascular Medicine
    • Physiology (medical)