TY - JOUR
T1 - MR angiography of tibial runoff vessels
T2 - Imaging with the head coil compared with conventional arteriography
AU - Cortell, Eric D.
AU - Kaufman, John A.
AU - Geller, Stuart C.
AU - Cambria, Richard P.
AU - Rivitz, S. Mitchell
AU - Waltman, Arthur C.
PY - 1996/7
Y1 - 1996/7
N2 - OBJECTIVE. We compared peripheral vascular MR angiography done with a standard transmit-receive head coil with conventional arteriography for identifying and evaluating runoff vessels below the knee. MATERIALS AND METHODS. We examined 55 legs in 31 symptomatic patients with both conventional contrast angiography and gradient-echo two-dimensional time-of- fight MR angiography. Both legs of patients were placed in a standard transmit-receive head coil for MR angiography and were imaged simultaneously. For evaluation of stenoses, images of vessels were divided into 10 segments, and each segments was graded on a four point scale. RESULTS. In the 393 native segments evaluated, the sensitivity of MR angiography in identifying normal vessels was 95% and the specificity was 98%. In detecting segmental occlusion, MR angiography was 98% sensitive and 97% specific. Sensitivity and specificity for stenoses greater than 75% were 98% and 96%, respectively, and for stenoses greater than 50%, they were 98% and 95%, respectively. Interpretative discrepancies were found in 35 vessel segments in 18 legs; none was of clinical relevance. Of all vessel segments shown as occluded by conventional angiography, 1% appeared patent on MR angiograms. No vessel segments shown as normal on MR angiograms were found to be concluded on conventional angiograms. CONCLUSION. When performed simultaneously on both legs of symptomatic patients, 2D time-of-flight MR angiography with a standard transmit-receive head coil provides a time-efficient and highly sensitive and specific means of evaluating below-knee runoff.
AB - OBJECTIVE. We compared peripheral vascular MR angiography done with a standard transmit-receive head coil with conventional arteriography for identifying and evaluating runoff vessels below the knee. MATERIALS AND METHODS. We examined 55 legs in 31 symptomatic patients with both conventional contrast angiography and gradient-echo two-dimensional time-of- fight MR angiography. Both legs of patients were placed in a standard transmit-receive head coil for MR angiography and were imaged simultaneously. For evaluation of stenoses, images of vessels were divided into 10 segments, and each segments was graded on a four point scale. RESULTS. In the 393 native segments evaluated, the sensitivity of MR angiography in identifying normal vessels was 95% and the specificity was 98%. In detecting segmental occlusion, MR angiography was 98% sensitive and 97% specific. Sensitivity and specificity for stenoses greater than 75% were 98% and 96%, respectively, and for stenoses greater than 50%, they were 98% and 95%, respectively. Interpretative discrepancies were found in 35 vessel segments in 18 legs; none was of clinical relevance. Of all vessel segments shown as occluded by conventional angiography, 1% appeared patent on MR angiograms. No vessel segments shown as normal on MR angiograms were found to be concluded on conventional angiograms. CONCLUSION. When performed simultaneously on both legs of symptomatic patients, 2D time-of-flight MR angiography with a standard transmit-receive head coil provides a time-efficient and highly sensitive and specific means of evaluating below-knee runoff.
UR - http://www.scopus.com/inward/record.url?scp=0029888851&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029888851&partnerID=8YFLogxK
U2 - 10.2214/ajr.167.1.8659360
DO - 10.2214/ajr.167.1.8659360
M3 - Article
C2 - 8659360
AN - SCOPUS:0029888851
SN - 0361-803X
VL - 167
SP - 147
EP - 151
JO - The American journal of roentgenology and radium therapy
JF - The American journal of roentgenology and radium therapy
IS - 1
ER -