TY - JOUR
T1 - Peripheral vascular disease
T2 - Blinded study of dedicated calf MR angiography versus standard bolus-chase MR angiography and film hard-copy angiography
AU - Binkert, Christoph A.
AU - Baker, Phillip D.
AU - Petersen, Bryan D.
AU - Szumowski, Jerzy
AU - Kaufman, John A.
PY - 2004/9
Y1 - 2004/9
N2 - PURPOSE: To compare the accuracy of contrast material-enhanced three-dimensional (3D) dedicated calf magnetic resonance (MR) angiography with that of bolus-chase MR angiography, with conventional angiography as the reference standard, in patients with symptomatic peripheral vascular disease (PVD). MATERIALS AND METHODS: Thirty men with symptomatic PVD were examined. MR angiography was performed at 1.5 T before conventional angiography. MR angiographic examination included 3D contrast-enhanced dedicated calf MR angiography and three-station bolus-chase MR angiography. Two radiologists blinded to conventional angiographic results evaluated the MR angiograms independently. Two angiographers evaluated the conventional angiograms in consensus. Calf artery segments were graded as having 50% or less stenosis, greater than 50% stenosis, or occlusion or as being nondiagnostic. Statistical analyses were performed with paired permutation testing. RESULTS: Analyses of 472 calf segments and 420 pelvic and thigh segments were performed. Of the 472 calf segments, three and 75 segments (reader 1) and seven and 91 segments (reader 2) were graded as nondiagnostic at dedicated calf MR angiography and bolus-chase MR angiography, respectively. Differences in diagnostic grade between the two examinations were significant (P < .001), accounting for within-subject correlations, with a mean estimated difference of -17.1% (95% confidence interval [CI]: -25.8%, -8.4%). In the calf arteries, the dedicated and bolus-chase MR angiographic sequences had diagnostic accuracies, respectively, of 81.5% (reader 1) and 79.1% (reader 2) and of 67.8% (reader 1) and 63.4% (reader 2). The dedicated calf sequence was significantly more accurate than the bolus-chase sequence (P = .001). The point estimate of the difference was 14.7%, with estimated correct diagnosis rates of 80.3% and 65.6% for the dedicated calf and bolus-chase examinations, respectively (95% CI for difference: 4.0%, 25.4%). The diagnostic accuracy of bolus-chase MR angiography at the pelvis-thigh level was slightly higher when it was performed first: 81.9% (reader 1) and 83.8% (reader 2) versus 74.3% (reader 1) and 80.0% (reader 2) when it was performed last. The difference was not significant (P = .21). CONCLUSION: Use of dedicated calf MR angiography led to significantly increased diagnostic accuracy in the calf arteries compared with standard bolus-chase MR angiography. Use of the dual-bolus technique did not jeopardize the diagnostic accuracy in the pelvic and thigh arteries.
AB - PURPOSE: To compare the accuracy of contrast material-enhanced three-dimensional (3D) dedicated calf magnetic resonance (MR) angiography with that of bolus-chase MR angiography, with conventional angiography as the reference standard, in patients with symptomatic peripheral vascular disease (PVD). MATERIALS AND METHODS: Thirty men with symptomatic PVD were examined. MR angiography was performed at 1.5 T before conventional angiography. MR angiographic examination included 3D contrast-enhanced dedicated calf MR angiography and three-station bolus-chase MR angiography. Two radiologists blinded to conventional angiographic results evaluated the MR angiograms independently. Two angiographers evaluated the conventional angiograms in consensus. Calf artery segments were graded as having 50% or less stenosis, greater than 50% stenosis, or occlusion or as being nondiagnostic. Statistical analyses were performed with paired permutation testing. RESULTS: Analyses of 472 calf segments and 420 pelvic and thigh segments were performed. Of the 472 calf segments, three and 75 segments (reader 1) and seven and 91 segments (reader 2) were graded as nondiagnostic at dedicated calf MR angiography and bolus-chase MR angiography, respectively. Differences in diagnostic grade between the two examinations were significant (P < .001), accounting for within-subject correlations, with a mean estimated difference of -17.1% (95% confidence interval [CI]: -25.8%, -8.4%). In the calf arteries, the dedicated and bolus-chase MR angiographic sequences had diagnostic accuracies, respectively, of 81.5% (reader 1) and 79.1% (reader 2) and of 67.8% (reader 1) and 63.4% (reader 2). The dedicated calf sequence was significantly more accurate than the bolus-chase sequence (P = .001). The point estimate of the difference was 14.7%, with estimated correct diagnosis rates of 80.3% and 65.6% for the dedicated calf and bolus-chase examinations, respectively (95% CI for difference: 4.0%, 25.4%). The diagnostic accuracy of bolus-chase MR angiography at the pelvis-thigh level was slightly higher when it was performed first: 81.9% (reader 1) and 83.8% (reader 2) versus 74.3% (reader 1) and 80.0% (reader 2) when it was performed last. The difference was not significant (P = .21). CONCLUSION: Use of dedicated calf MR angiography led to significantly increased diagnostic accuracy in the calf arteries compared with standard bolus-chase MR angiography. Use of the dual-bolus technique did not jeopardize the diagnostic accuracy in the pelvic and thigh arteries.
KW - Angiography, comparative studies
KW - Arteries, MR
KW - Arteries, extremities
KW - Arteries, stenosis or obstruction
KW - Magnetic resonance (MR), vascular, studies
UR - http://www.scopus.com/inward/record.url?scp=4143084780&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=4143084780&partnerID=8YFLogxK
U2 - 10.1148/radiol.2323030244
DO - 10.1148/radiol.2323030244
M3 - Article
C2 - 15333800
AN - SCOPUS:4143084780
SN - 0033-8419
VL - 232
SP - 860
EP - 866
JO - RADIOLOGY
JF - RADIOLOGY
IS - 3
ER -