TY - JOUR
T1 - Predictors of Vision-Related Quality of Life After Endothelial Keratoplasty in the Descemet Endothelial Thickness Comparison Trials
AU - Pickel, Julia
AU - Chamberlain, Winston D.
AU - Lin, Charles C.
AU - Austin, Ariana
AU - Clover, Jameson
AU - Lietman, Thomas M.
AU - Rose-Nussbaumer, Jennifer
N1 - Funding Information:
This work was supported by grants K23 EY025025 (J. Rose-Nussbaumer) from the National Eye Institute and Research to Prevent Blindness.
Publisher Copyright:
Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2021/4/1
Y1 - 2021/4/1
N2 - Purpose: To determine which baseline characteristics are associated with vision-related quality of life (QOL) after endothelial keratoplasty. Methods: A patient- and outcome-masked randomized clinical trial. Consecutive patients presenting with isolated endothelial disease requiring endothelial keratoplasty at Oregon Health Sciences University and Stanford University. Study eyes randomized to one of the 2 types of endothelial keratoplasty were given the national eye institute vision function questionnaire 25 at baseline and 12 months. In this prespecified secondary outcome, we assessed the role of recipient and donor characteristics as predictors of the 12-month national eye institute vision function questionnaire 25 change score. Results: The mean vision function questionnaire (VFQ) score was 74 (SD 14) at baseline and increased to 82 (SD 12) at 3 months and 87 (SD 10) at 12 months. We were unable to find a difference in vision-related QOL in study participants who underwent Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping endothelial keratoplasty [coef 20.98, 95% confidence interval (CI) 29.27 to 7.31; P = 0.82]. In multivariable analysis, patients who underwent endothelial keratoplasty in 2 eyes had approximately 8 points higher VFQ at 12 months after the second eye than those who had only one eye enrolled (95% CI 0.10-15.72; P = 0.047). Posterior densitometry produced an approximately 1-point increase each in the VFQ change score for each 1 grayscale unit increase at baseline (95% CI 0.26-1.81; P = 0.009). Although the sample size was small, a diagnosis of pseudophakic bullous keratopathy had approximately 19-points more improvement on average compared with Fuchs (95% CI 7.68-30.00; P = 0.001). Conclusions: Bilateral endothelial keratoplasty resulted in higher vision-related QOL compared with unilateral. Baseline densitometry, objective measure of corneal haze that predicts vision-related QOL, may play a role in monitoring disease progression.
AB - Purpose: To determine which baseline characteristics are associated with vision-related quality of life (QOL) after endothelial keratoplasty. Methods: A patient- and outcome-masked randomized clinical trial. Consecutive patients presenting with isolated endothelial disease requiring endothelial keratoplasty at Oregon Health Sciences University and Stanford University. Study eyes randomized to one of the 2 types of endothelial keratoplasty were given the national eye institute vision function questionnaire 25 at baseline and 12 months. In this prespecified secondary outcome, we assessed the role of recipient and donor characteristics as predictors of the 12-month national eye institute vision function questionnaire 25 change score. Results: The mean vision function questionnaire (VFQ) score was 74 (SD 14) at baseline and increased to 82 (SD 12) at 3 months and 87 (SD 10) at 12 months. We were unable to find a difference in vision-related QOL in study participants who underwent Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping endothelial keratoplasty [coef 20.98, 95% confidence interval (CI) 29.27 to 7.31; P = 0.82]. In multivariable analysis, patients who underwent endothelial keratoplasty in 2 eyes had approximately 8 points higher VFQ at 12 months after the second eye than those who had only one eye enrolled (95% CI 0.10-15.72; P = 0.047). Posterior densitometry produced an approximately 1-point increase each in the VFQ change score for each 1 grayscale unit increase at baseline (95% CI 0.26-1.81; P = 0.009). Although the sample size was small, a diagnosis of pseudophakic bullous keratopathy had approximately 19-points more improvement on average compared with Fuchs (95% CI 7.68-30.00; P = 0.001). Conclusions: Bilateral endothelial keratoplasty resulted in higher vision-related QOL compared with unilateral. Baseline densitometry, objective measure of corneal haze that predicts vision-related QOL, may play a role in monitoring disease progression.
KW - DMEK
KW - DSAEK
KW - Endothelial keratoplasty
KW - Vision-related quality of life
UR - http://www.scopus.com/inward/record.url?scp=85106098841&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85106098841&partnerID=8YFLogxK
U2 - 10.1097/ICO.0000000000002431
DO - 10.1097/ICO.0000000000002431
M3 - Article
C2 - 33881810
AN - SCOPUS:85106098841
SN - 0277-3740
VL - 40
SP - 449
EP - 452
JO - Cornea
JF - Cornea
IS - 4
ER -