TY - JOUR
T1 - Quantifying Coronal Tooth Discoloration Caused by Biodentine and EndoSequence Root Repair Material
AU - Beatty, Hannah
AU - Svec, Timothy
N1 - Funding Information:
Supported by the AAE Foundation and the OHSU Department of Endodontology Les Morgan Endowment Fund .
Publisher Copyright:
© 2015 American Association of Endodontists.
PY - 2015
Y1 - 2015
N2 - Introduction Mineral trioxide aggregate (ProRoot [PR]; Dentsply, Tulsa, OK) has been shown to have high rates of success in various endodontic applications. A major drawback is its tendency to discolor dentin. Two new bioceramics (BD, Biodentine [BD]; Septodont, Saint Maur des Fosses, France; and EndoSequence [ES]; Brasseler, Savannah, GA) have been developed that claim to not discolor teeth. The aim of this study was to compare tooth discoloration between these 3 materials. Methods Forty-eight bovine mandibular incisors (4 groups, n = 12) were obtained and prepared from the apical aspect after root resection. Canals were prepared with sequentially larger ParaPost drills (Coltene/Whaledent Inc, Cuyahoga Falls, OH) to size 7 to 3 mm coronal to the cementoenamel junction. Experimental materials were condensed into the crowns and the access sealed. Color was assessed at various times up to 2 months according to the CIE L∗a∗b∗color space system. Change in color, ΔE, was compared among groups and over time using analysis of variance. Results For all materials, there was a sharp increase in ΔE after placement. There was a rebound effect on day 1. After a rebound toward the initial color, all materials displayed a trend toward discoloration through the experimental period. At the end of 8 weeks, both BD and ES had discolored significantly more than either control or PR. BD and ES were not significantly different from each other. Control and PR were not significantly different from one another at the end of the experimental period. Conclusions BD and ES discolor bovine tooth structure to a perceptible degree. At 8 weeks, this was significantly more than PR.
AB - Introduction Mineral trioxide aggregate (ProRoot [PR]; Dentsply, Tulsa, OK) has been shown to have high rates of success in various endodontic applications. A major drawback is its tendency to discolor dentin. Two new bioceramics (BD, Biodentine [BD]; Septodont, Saint Maur des Fosses, France; and EndoSequence [ES]; Brasseler, Savannah, GA) have been developed that claim to not discolor teeth. The aim of this study was to compare tooth discoloration between these 3 materials. Methods Forty-eight bovine mandibular incisors (4 groups, n = 12) were obtained and prepared from the apical aspect after root resection. Canals were prepared with sequentially larger ParaPost drills (Coltene/Whaledent Inc, Cuyahoga Falls, OH) to size 7 to 3 mm coronal to the cementoenamel junction. Experimental materials were condensed into the crowns and the access sealed. Color was assessed at various times up to 2 months according to the CIE L∗a∗b∗color space system. Change in color, ΔE, was compared among groups and over time using analysis of variance. Results For all materials, there was a sharp increase in ΔE after placement. There was a rebound effect on day 1. After a rebound toward the initial color, all materials displayed a trend toward discoloration through the experimental period. At the end of 8 weeks, both BD and ES had discolored significantly more than either control or PR. BD and ES were not significantly different from each other. Control and PR were not significantly different from one another at the end of the experimental period. Conclusions BD and ES discolor bovine tooth structure to a perceptible degree. At 8 weeks, this was significantly more than PR.
KW - Biodentine
KW - EndoSequence
KW - Pro Root
KW - discoloration
KW - mineral trioxide aggregate
UR - http://www.scopus.com/inward/record.url?scp=84951310783&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84951310783&partnerID=8YFLogxK
U2 - 10.1016/j.joen.2015.08.032
DO - 10.1016/j.joen.2015.08.032
M3 - Article
C2 - 26472676
AN - SCOPUS:84951310783
SN - 0099-2399
VL - 41
SP - 2036
EP - 2039
JO - Journal of Endodontics
JF - Journal of Endodontics
IS - 12
ER -