T1 - Radiographic Diagnosis of Aortic-Ball Variance
AU - Hylen, John C.
AU - Judkins, Melvin P.
AU - Herr, Rodney H.
AU - Starr, Albert
PY - 1969/2/10
Y1 - 1969/2/10
N2 - Assessing changes in the silicone-rubber ball of the Model 1000 series Starr-Edwards aortic-valve prosthesis is an increasingly frequent diagnostic problem. Bariumimpregnated, silicone-rubber balls have been available since 1962. Presently, these constitute slightly less than 10% of all silicon-rubber balls distributed. Radiographic evidence of aortic-ball variance was obtained for a patient having normal sounds of the prosthetic aortic valve as determined by auscultation, phonocardiography, and sound spectrography. All silicone-rubber balls now produced by the manufacturer are barium-impregnated; henceforth, radiographic techniques will be more uniformly applicable to the early diagnosis of aortic-ball variance. Since most patients with aortic-ball variance are asymptomatic, routine screening for the early detection of ball variance is suggested for all patients with barium-impregnated, silicone-rubber balls. Serial high-resolution films and cineradiography should be used.
AB - Assessing changes in the silicone-rubber ball of the Model 1000 series Starr-Edwards aortic-valve prosthesis is an increasingly frequent diagnostic problem. Bariumimpregnated, silicone-rubber balls have been available since 1962. Presently, these constitute slightly less than 10% of all silicon-rubber balls distributed. Radiographic evidence of aortic-ball variance was obtained for a patient having normal sounds of the prosthetic aortic valve as determined by auscultation, phonocardiography, and sound spectrography. All silicone-rubber balls now produced by the manufacturer are barium-impregnated; henceforth, radiographic techniques will be more uniformly applicable to the early diagnosis of aortic-ball variance. Since most patients with aortic-ball variance are asymptomatic, routine screening for the early detection of ball variance is suggested for all patients with barium-impregnated, silicone-rubber balls. Serial high-resolution films and cineradiography should be used.
UR - http://www.scopus.com/inward/record.url?scp=0014669382&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0014669382&partnerID=8YFLogxK
U2 - 10.1001/jama.1969.03150190042008
DO - 10.1001/jama.1969.03150190042008
M3 - Article
C2 - 5818243
AN - SCOPUS:0014669382
SN - 0098-7484
VL - 207
SP - 1120
EP - 1122
JO - JAMA: The Journal of the American Medical Association
JF - JAMA: The Journal of the American Medical Association
IS - 6
ER -