TY - JOUR
T1 - The porous polyethylene/bioglass spherical orbital implant
T2 - A retrospective study of 170 cases
AU - Ma, Xiaoping
AU - Schou, Kevin R.
AU - Maloney-Schou, Maureen
AU - Harwin, Fredric M.
AU - Ng, John D.
PY - 2011/1
Y1 - 2011/1
N2 - Purpose: To report patient outcomes after placement of porous polyethylene (PPE)/bioglass (BG) orbital implants for primary enucleation or secondary implantation. DESIGN:: Retrospective chart review in one surgeon's practice (J.D.N.). Methods: A chart review of all patients who underwent placement of PPE/BG orbital implants was performed. Data included patient's age, gender, surgical indication, prior ocular surgery, medical history, procedure performed, implant size, and postoperative complications. Results: PPE/BG implants were placed in 170 sockets. Seventy-seven patients were women, and 85 were men. One hundred forty patients underwent primary enucleation and placement of an implant, and 22 patients underwent secondary implantation. One hundred sixty-one patients did well after orbital implantation with a comfortable socket, quiet conjunctiva, and motility. Complications occurred in 9 patients (5.3%). Excessive discharge alone occurred in 2 patients (1.2%). Seven sockets undergoing primary enucleation and implant placement had implant exposure. One patient had an early exposure, and 6 had late exposures. All exposures were successfully treated with antibiotics or additional surgery. Secondary surgeries were required by some patients, but not due to implant complications, included ectropion repair in 5 patients (2.9%) and volume augmentation in 3 patients (1.7%). CONCLUSIONS:: The PPE/BG orbital implant may be a useful implant for orbital reconstruction after primary enucleation or as a secondary implant.
AB - Purpose: To report patient outcomes after placement of porous polyethylene (PPE)/bioglass (BG) orbital implants for primary enucleation or secondary implantation. DESIGN:: Retrospective chart review in one surgeon's practice (J.D.N.). Methods: A chart review of all patients who underwent placement of PPE/BG orbital implants was performed. Data included patient's age, gender, surgical indication, prior ocular surgery, medical history, procedure performed, implant size, and postoperative complications. Results: PPE/BG implants were placed in 170 sockets. Seventy-seven patients were women, and 85 were men. One hundred forty patients underwent primary enucleation and placement of an implant, and 22 patients underwent secondary implantation. One hundred sixty-one patients did well after orbital implantation with a comfortable socket, quiet conjunctiva, and motility. Complications occurred in 9 patients (5.3%). Excessive discharge alone occurred in 2 patients (1.2%). Seven sockets undergoing primary enucleation and implant placement had implant exposure. One patient had an early exposure, and 6 had late exposures. All exposures were successfully treated with antibiotics or additional surgery. Secondary surgeries were required by some patients, but not due to implant complications, included ectropion repair in 5 patients (2.9%) and volume augmentation in 3 patients (1.7%). CONCLUSIONS:: The PPE/BG orbital implant may be a useful implant for orbital reconstruction after primary enucleation or as a secondary implant.
UR - http://www.scopus.com/inward/record.url?scp=78751646922&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78751646922&partnerID=8YFLogxK
U2 - 10.1097/IOP.0b013e3181de01a7
DO - 10.1097/IOP.0b013e3181de01a7
M3 - Article
C2 - 20700071
AN - SCOPUS:78751646922
SN - 0740-9303
VL - 27
SP - 21
EP - 27
JO - Ophthalmic Plastic and Reconstructive Surgery
JF - Ophthalmic Plastic and Reconstructive Surgery
IS - 1
ER -