Skip to main navigation Skip to search Skip to main content

Ultrasound biomicroscopy before and after goniosynechialysis

  • Oscar Andrew Q. Canlas
  • , Hiroshi Ishikawa
  • , Jeffrey M. Liebmann
  • , Celso Tello
  • , Robert Ritch

Research output: Contribution to journal › Article › peer-review

Abstract

PURPOSE: To report the ultrasound biomicroscopic appearance of the anterior chamber angle before and after successful goniosynechialysis.METHODS: Interventional case report. Ultrasound biomicroscopy using a 50-MHz transducer was performed in the supine position preoperatively and postoperatively in a 76-year-old woman with angle-closure glaucoma. RESULTS: Ultrasound biomicroscopy of the anterior chamber angle demonstrated restoration of an open anterior chamber angle after goniosynechialysis. CONCLUSION: High-resolution imaging of the anterior segment to evaluate preoperative and postoperative anatomy may be useful in eyes undergoing goniosynechialysis.

Original languageEnglish (US)
Pages (from-to)570-571
Number of pages2
JournalAmerican journal of ophthalmology
Volume132
Issue number4
DOIs
StatePublished - 2001
Externally publishedYes

Funding

Supported in part by the Corinne Graber Research Fund of the New York Glaucoma Research Institute.

Funders
Barnett and Annette Ostrow Research Fund of the New York Glaucoma Research Institute, New York

    ASJC Scopus subject areas

    • Ophthalmology

    Fingerprint

    Dive into the research topics of 'Ultrasound biomicroscopy before and after goniosynechialysis'. Together they form a unique fingerprint.

    Cite this