Abstract
Objectives: We describe a technique of doubly clipping the distal ureter during hand-assisted laparoscopic donor nephrectomy (HALDN) to prevent urine accumulation, thereby simplifying renal hilar division and potentially decreasing the graft warm ischemic time. Methods: A technique of placing polymer-locking clips across the distal ureter prior to division was developed to prevent urine accumulation and the need for suctioning during critical hilar vessel division. Results: We found that ureteral clipping and the elimination of urine accumulation simplified renal hilar division. Retrospective assessment of a series of 27 sequential HALDNs (15 without and 12 with clipping) demonstrated similar estimated blood loss, total operative and warm ischemic times (P=0.13 to 0.18). No adverse impact on graft viability or recipient outcome was observed. Conclusion: Distal ureter clipping to prevent urine accumulation around the renal hilum during HALDN is safe and helpful.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 531-533 |
| Number of pages | 3 |
| Journal | Journal of the Society of Laparoendoscopic Surgeons |
| Volume | 14 |
| Issue number | 4 |
| DOIs | |
| State | Published - Oct 2011 |
| Externally published | Yes |
Keywords
- Donor
- Laparoscopy
- Nephrectomy
- Ureter
ASJC Scopus subject areas
- Surgery
Fingerprint