TY - JOUR
T1 - Vitamin D deficiency during the perioperative period increases the rate of hardware failure and the need for revision fusion in adult patients undergoing single-level lumbar spine instrumentation surgery
AU - Robison, Bianca
AU - Wright, Christina
AU - Smith, Spencer
AU - Philipp, Travis
AU - Yoo, Jung
N1 - Funding Information:
Author disclosures: BR: Nothing to disclose. CW: Nothing to disclose. SS: Nothing to disclose. TP: Nothing to disclose. JY: Grants: Ortofix Inc. (C). Royalties: Osiris Therapeutics Inc. (B).
Publisher Copyright:
© 2022
PY - 2023/3
Y1 - 2023/3
N2 - Background: Vitamin D has been shown to play important roles in both calcium homeostasis and bone healing. Only three studies have directly examined the relationship between vitamin D deficiency and hardware failure, nonunion, and/or revision surgery. Results are contradictory and none were large enough to provide the statistical power necessary to make definitive conclusions. Methods: A retrospective analysis was performed utilizing the PearlDiver national insurance claims database consisting of 91 million individual patient records. Patients aged 30 and over who underwent a non-segmental posterior lumbar fusion procedure (CPT-22840) in 2012-2019 were included. Data collected included, hardware failure, revision surgery occurrence, and vitamin D deficiency. Hardware failure and revision rates were compared between vitamin D deficient and non-deficient groups. We ran a logistic regression analysis using the following variables: age, Charlson Comorbidity Index (CCI), gender, vitamin D deficiency, obesity, tobacco use, diabetes, osteoporosis, rheumatoid arthritis, and Crohn's disease. Results: 108,137 patients matching inclusion criteria were identified, with an overall hardware failure rate of 2.7% and revision rate of 4.1%. Failure rates were significantly higher for patients diagnosed with vitamin D deficiency during the full queried period (3.3% vs. 2.6%, OR = 1.26; p < 0.0001), as were revision rates (4.3% vs 3.5%, OR = 1.25; p < 0.0001). Patients diagnosed with deficiency pre-surgery, higher failure (3.1% vs 2.6%, OR = 1.19; p < 0.01) and rates of revision (4.4% vs 3.5%, OR = 1.27; p < 0.0001) were increased compared to the non-deficient group. In the logistic regression analysis, vitamin D deficiency remains a significant contributor to hardware failure and revision surgery. Conclusions: These results demonstrate that pre- and/or post-operative vitamin D deficiency is independently correlated with risk for hardware failure and revision surgery in single-level lumbar fusion patients.
AB - Background: Vitamin D has been shown to play important roles in both calcium homeostasis and bone healing. Only three studies have directly examined the relationship between vitamin D deficiency and hardware failure, nonunion, and/or revision surgery. Results are contradictory and none were large enough to provide the statistical power necessary to make definitive conclusions. Methods: A retrospective analysis was performed utilizing the PearlDiver national insurance claims database consisting of 91 million individual patient records. Patients aged 30 and over who underwent a non-segmental posterior lumbar fusion procedure (CPT-22840) in 2012-2019 were included. Data collected included, hardware failure, revision surgery occurrence, and vitamin D deficiency. Hardware failure and revision rates were compared between vitamin D deficient and non-deficient groups. We ran a logistic regression analysis using the following variables: age, Charlson Comorbidity Index (CCI), gender, vitamin D deficiency, obesity, tobacco use, diabetes, osteoporosis, rheumatoid arthritis, and Crohn's disease. Results: 108,137 patients matching inclusion criteria were identified, with an overall hardware failure rate of 2.7% and revision rate of 4.1%. Failure rates were significantly higher for patients diagnosed with vitamin D deficiency during the full queried period (3.3% vs. 2.6%, OR = 1.26; p < 0.0001), as were revision rates (4.3% vs 3.5%, OR = 1.25; p < 0.0001). Patients diagnosed with deficiency pre-surgery, higher failure (3.1% vs 2.6%, OR = 1.19; p < 0.01) and rates of revision (4.4% vs 3.5%, OR = 1.27; p < 0.0001) were increased compared to the non-deficient group. In the logistic regression analysis, vitamin D deficiency remains a significant contributor to hardware failure and revision surgery. Conclusions: These results demonstrate that pre- and/or post-operative vitamin D deficiency is independently correlated with risk for hardware failure and revision surgery in single-level lumbar fusion patients.
KW - Database
KW - Hardware failure
KW - Lumbar
KW - Lumbar fusion
KW - PearlDiver
KW - Revision surgery
KW - Vitamin D
KW - Vitamin d deficiency
UR - http://www.scopus.com/inward/record.url?scp=85145847017&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85145847017&partnerID=8YFLogxK
U2 - 10.1016/j.xnsj.2022.100197
DO - 10.1016/j.xnsj.2022.100197
M3 - Article
AN - SCOPUS:85145847017
SN - 2666-5484
VL - 13
JO - North American Spine Society Journal
JF - North American Spine Society Journal
M1 - 100197
ER -