A combination of experimental and finite element analyses of needle–tissue interaction to compute the stresses and deformations during injection at different angles

Mahdi Halabian, Borhan Beigzadeh, Alireza Karimi, Hadi Asgharzadeh Shirazi, Mohammad Hasan Shaali

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

One of the main clinical applications of the needles is its practical usage in the femoral vein catheterization. Annually more than two million peoples in the United States are exposed to femoral vein catheterization. How to use the input needles into the femoral vein has a key role in the sense of pain in post-injection and possible injuries, such as tissue damage and bleeding. It has been shown that there might be a correlation between the stresses and deformations due to femoral injection to the tissue and the sense of pain and, consequently, injuries caused by needles. In this study, the stresses and deformations induced by the needle to the femoral tissue were experimentally and numerically investigated in response to an input needle at four different angles, i.e., 30°, 45°, 60°, and 90°, via finite element method. In addition, a set of experimental injections at different angles were carried out to compare the numerical results with that of the experimental ones, namely pain score. The results revealed that by increasing the angle of injection up to 60°, the strain at the interaction site of the needle–tissue is increased accordingly while a significant falling is observed at the angle of 90°. In contrast, the stress due to injection was decreased at the region of needle–tissue interaction with showing the lowest one at the angle of 90°. Experimental results were also well confirmed the numerical observations since the lowest pain score was seen at the angle of 90°. The results suggest that the most effective angle of injection would be 90° due to a lower amount of stresses and deformations compared to the other angles of injection. These findings may have implications not only for understating the stresses and deformations induced during injection around the needle–tissue interaction, but also to give an outlook to the doctors to implement the most suitable angle of injection in order to reduce the pain as well as post injury of the patients.

Original languageEnglish (US)
Pages (from-to)965-975
Number of pages11
JournalJournal of Clinical Monitoring and Computing
Volume30
Issue number6
DOIs
StatePublished - Dec 1 2016
Externally publishedYes

Keywords

  • Angle of injection
  • Finite element modeling
  • Needle–tissue interaction
  • Pain score
  • Vein tissue

ASJC Scopus subject areas

  • Health Informatics
  • Critical Care and Intensive Care Medicine
  • Anesthesiology and Pain Medicine

Fingerprint