A randomized study of intravenous fluid replacement following living-donor renal transplantation

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Fourteen adult recipients of living-donor kidneys preserved with ice-cold intracellular electrolyte solution were randomly assigned to receive either high fluid replacement (total volume of urine output + 30 ml/hr) or low fluid replacement (constant 125 ml/hr) during the first 48 hr after grafting. High replacement recipients had significantly higher fluid intake and urine output than did low replacement recipients. However, net fluid balance at the end of the 48-hr study period was positive for both groups and not significantly different. Fractional excretion of sodium was directly related to urine output in all patients. Serum osmolality, serum sodium concentration, and urine sodium concentration were not significantly different in the treatment groups. Urine osmolality was significantly higher in the lowreplacement group at 24 and 36 hr after transplantation. The i.v. replacement of total urinary output is unnecessary in adult recipients of living-donor kidneys preserved with ice-cold intracellular electrolyte solution because such grafts can conserve sodium and water immediately after transplantation.

Original languageEnglish (US)
Pages (from-to)648-650
Number of pages3
JournalTransplantation
Volume40
Issue number6
DOIs
StatePublished - Dec 1985

ASJC Scopus subject areas

  • Transplantation

Fingerprint

Dive into the research topics of 'A randomized study of intravenous fluid replacement following living-donor renal transplantation'. Together they form a unique fingerprint.

Cite this