A statewide teleradiology system reduces radiation exposure and charges in transferred trauma patients

Justin J.J. Watson, Alexis Moren, Brian Diggs, Ben Houser, Lynn Eastes, Dawn Brand, Pamela Bilyeu, Martin Schreiber, Laszlo Kiraly

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Background Trauma transfer patients routinely undergo repeat imaging because of inefficiencies within the radiology system. In 2009, the virtual private network (VPN) telemedicine system was adopted throughout Oregon allowing virtual image transfer between hospitals. The startup cost was a nominal $3,000 per hospital. Methods A retrospective review from 2007 to 2012 included 400 randomly selected adult trauma transfer patients based on a power analysis (200 pre/200 post). The primary outcome evaluated was reduction in repeat computed tomography (CT) scans. Secondary outcomes included cost savings, emergency department (ED) length of stay (LOS), and spared radiation. All data were analyzed using Mann-Whitney U and chi-square tests. P less than.05 indicated significance. Spared radiation was calculated as a weighted average per body region, and savings was calculated using charges obtained from Oregon Health and Science University radiology current procedural terminology codes. Results Four-hundred patients were included. Injury Severity Score, age, ED and overall LOS, mortality, trauma type, and gender were not statistically different between groups. The percentage of patients with repeat CT scans decreased after VPN implementation: CT abdomen (13.2% vs 2.8%, P <.01) and cervical spine (34.4% vs 18.2%, P <.01). Post-VPN, the total charges saved in 2012 for trauma transfer patients was $333,500, whereas the average radiation dose spared per person was 1.8 mSV. Length of stay in the ED for patients with Injury Severity Score less than 15 transferring to the ICU was decreased (P <.05). Conclusions Implementation of a statewide teleradiology network resulted in fewer total repeat CT scans, significant savings, decrease in radiation exposure, and decreased LOS in the ED for patients with less complex injuries. The potential for health care savings by widespread adoption of a VPN is significant.

Original languageEnglish (US)
Pages (from-to)908-912
Number of pages5
JournalAmerican journal of surgery
Volume211
Issue number5
DOIs
StatePublished - May 1 2016

Keywords

  • Charges
  • Decreased
  • Radiation
  • Reduction
  • Statewide
  • Teleradiology

ASJC Scopus subject areas

  • Surgery

Fingerprint

Dive into the research topics of 'A statewide teleradiology system reduces radiation exposure and charges in transferred trauma patients'. Together they form a unique fingerprint.

Cite this