TY - JOUR
T1 - Biological magnetic resonance imaging using laser-polarized 129Xe
AU - Albert, M. S.
AU - Cates, G. D.
AU - Driehuys, B.
AU - Happer, W.
AU - Saam, B.
AU - Springer, C. S.
AU - Wishnia, A.
PY - 1994/1/1
Y1 - 1994/1/1
N2 - As currently implemented, magnetic resonance imaging (MRI) relies on the protons of water molecules in tissue to provide the NMR signal. Protons are, however, notoriously difficult to image in some biological environments of interest, notably the lungs1 and lipid bilayer membranes such as those in the brain2. Here we show that 129Xe gas can be used for high-resolution MRI when the nuclear-spin polarization of the atoms is increased by laser optical pumping and spin exchange3-6. This process produces hyperpolarized 129Xe, in which the magnetization is enhanced by a factor of about 105. By introducing hyperpolarized 129Xe into mouse lungs we have obtained images of the lung gas space with a speed and a resolution better than those available from proton MRI 1,7 or emission tomography8,9. As xenon (a safe general anaesthetic) is rapidly and safely trans-ferred from the lungs to blood and thence to other tissues8,9, where it is concentrated in lipid 10-15 and protein13,15-18 components, images of the circulatory system, the brain and other vital organs can also be obtained. Because the magnetic behaviour of 129Xe is very sensi-tive to its environment, and is different from that of 1H2O, MRI using hyperpolarized 129Xe should involve distinct and sensitive mechanisms for tissue contrast.
AB - As currently implemented, magnetic resonance imaging (MRI) relies on the protons of water molecules in tissue to provide the NMR signal. Protons are, however, notoriously difficult to image in some biological environments of interest, notably the lungs1 and lipid bilayer membranes such as those in the brain2. Here we show that 129Xe gas can be used for high-resolution MRI when the nuclear-spin polarization of the atoms is increased by laser optical pumping and spin exchange3-6. This process produces hyperpolarized 129Xe, in which the magnetization is enhanced by a factor of about 105. By introducing hyperpolarized 129Xe into mouse lungs we have obtained images of the lung gas space with a speed and a resolution better than those available from proton MRI 1,7 or emission tomography8,9. As xenon (a safe general anaesthetic) is rapidly and safely trans-ferred from the lungs to blood and thence to other tissues8,9, where it is concentrated in lipid 10-15 and protein13,15-18 components, images of the circulatory system, the brain and other vital organs can also be obtained. Because the magnetic behaviour of 129Xe is very sensi-tive to its environment, and is different from that of 1H2O, MRI using hyperpolarized 129Xe should involve distinct and sensitive mechanisms for tissue contrast.
UR - http://www.scopus.com/inward/record.url?scp=0028466202&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0028466202&partnerID=8YFLogxK
U2 - 10.1038/370199a0
DO - 10.1038/370199a0
M3 - Article
C2 - 8028666
AN - SCOPUS:0028466202
SN - 0028-0836
VL - 370
SP - 199
EP - 201
JO - Nature
JF - Nature
IS - 6486
ER -