Corneal ectasia detection by epithelial pattern standard deviation from OCT

Marcella Q. Salomão, Ana Luisa Hofling-Lima, Louise Pellegrino Gomes Esporcatte, Fernando Faria Correa, Erica Ferreira Meneses, Yan Li, David Huang, Bernardo Lopes, Nelson Sena, Aydano P. MacHado, Renato Ambrósio

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose:To test the ability of the corneal epithelial pattern standard deviation (PSD) to distinguish between normal and cases with corneal ectatic condition.Setting:Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil.Design:Cross-sectional retrospective study.Methods:Patients were stratified into 4 groups based on clinical data and corneal tomography. Groups 1 and 2 comprised 1 eye randomly selected from 105 patients with normal corneas (N) and 86 patients with bilateral keratoconus (KC). Groups 3 and 4, respectively, comprised 11 ectatic eyes with no surgical treatment for KC (very asymmetric ectasia [VAE]-E) from patients whose fellow eyes (61) presented with normal topographic patterns (VAE-NT). Corneas were scanned using an OCT system (RT Vue) and Scheimpflug corneal tomography (Pentacam) and also had biomechanical assessment through the Corvis ST. Corneal epithelial thickness maps were analyzed, and the PSD value was calculated. The area under the receiver operating characteristic curve analysis was used to evaluate the diagnostic accuracy of the indices.Results:A total of 105 normal eyes, 86 keratoconic eyes, and 11 ectatic eyes whose fellow eyes (61) presented normal topographic patterns were evaluated. Epithelial PSD was significantly different across the 4 groups (P <.0001). The pairwise comparison revealed that the normal group presented significantly lower values than both ectasia groups (KC and VAE-E, P <.0001) and the VAE-NT group (P =.0008). There was no statistical significant difference between KC and VAE-E (P =.4284), while they were significantly higher than the VAE-NT group (P <.0001 and P =.0004).Conclusions:Epithelial PSD can be used to detect abnormal epithelial thickness patterns. Corneal epithelial thickness changes could be detected accurately in patients with KC, even in the form fruste of the disease.

Original languageEnglish (US)
Pages (from-to)190-194
Number of pages5
JournalJournal of cataract and refractive surgery
Volume49
Issue number2
DOIs
StatePublished - Feb 1 2023

ASJC Scopus subject areas

  • General Medicine

Fingerprint

Dive into the research topics of 'Corneal ectasia detection by epithelial pattern standard deviation from OCT'. Together they form a unique fingerprint.

Cite this