TY - JOUR
T1 - Diffusion-weighted MR imaging for the assessment of renal function
T2 - Analysis using statistical models based on truncated gaussian and gamma distributions
AU - Yamada, Kentaro
AU - Shinmoto, Hiroshi
AU - Oshio, Koichi
AU - Ito, Seigo
AU - Kumagai, Hiroo
AU - Kaji, Tatsumi
N1 - Publisher Copyright:
© 2015 Japanese Society for Magnetic Resonance in Medicine.
PY - 2016/4/11
Y1 - 2016/4/11
N2 - Purpose: To determine the appropriateness of statistical models using the truncated Gaussian distribution and gamma distribution for diffusion signal decay, and to assess the correlation between the parameters obtained from the statistical models and estimated glomerular filtration rate (eGFR). Methods: Twenty-nine patients with chronic kidney disease and 21 healthy volunteers were included and classified in four groups according to eGFR (ml/min/1.73 m2): group 1 (90 ≤ eGFR, n = 10), group 2 (eGFR 60–90, n = 15), group 3 (eGFR 30–60, n = 17), and group 4 (eGFR < 30, n = 8). Diffusion-weighted imaging using five b-values (0, 500, 1000, 1500, and 2000 s/mm2) was performed. Truncated Gaussian and gamma models were compared for goodness of fit. Area fractions for the diffusion coefficient D < 1.0 × 10-3 mm2/s (Frac < 1.0) and D > 3.0 × 10-3 mm2/s (Frac > 3.0) obtained from the statistical model were compared among four groups. Correlation between proposed parameters and conventional apparent diffusion coefficient (ADC) with eGFR was calculated. Results: There was no significant difference in goodness of fit between the truncated Gaussian and gamma models. Frac < 1.0 and Frac > 3.0 showed good correlation with eGFR, as did ADC. Comparison between groups 1 and 2 showed that only Frac < 1.0 in both distribution models had significant differences. Conclusion: Statistical models yield robust interpretation of diffusion magnetic resonance (MR) signals with relevance to histological changes in the kidney. The parameters of the statistical models, particularly Frac < 1.0, strongly correlated with eGFR.
AB - Purpose: To determine the appropriateness of statistical models using the truncated Gaussian distribution and gamma distribution for diffusion signal decay, and to assess the correlation between the parameters obtained from the statistical models and estimated glomerular filtration rate (eGFR). Methods: Twenty-nine patients with chronic kidney disease and 21 healthy volunteers were included and classified in four groups according to eGFR (ml/min/1.73 m2): group 1 (90 ≤ eGFR, n = 10), group 2 (eGFR 60–90, n = 15), group 3 (eGFR 30–60, n = 17), and group 4 (eGFR < 30, n = 8). Diffusion-weighted imaging using five b-values (0, 500, 1000, 1500, and 2000 s/mm2) was performed. Truncated Gaussian and gamma models were compared for goodness of fit. Area fractions for the diffusion coefficient D < 1.0 × 10-3 mm2/s (Frac < 1.0) and D > 3.0 × 10-3 mm2/s (Frac > 3.0) obtained from the statistical model were compared among four groups. Correlation between proposed parameters and conventional apparent diffusion coefficient (ADC) with eGFR was calculated. Results: There was no significant difference in goodness of fit between the truncated Gaussian and gamma models. Frac < 1.0 and Frac > 3.0 showed good correlation with eGFR, as did ADC. Comparison between groups 1 and 2 showed that only Frac < 1.0 in both distribution models had significant differences. Conclusion: Statistical models yield robust interpretation of diffusion magnetic resonance (MR) signals with relevance to histological changes in the kidney. The parameters of the statistical models, particularly Frac < 1.0, strongly correlated with eGFR.
KW - Chronic kidney disease
KW - Estimated glomerular filtration rate
KW - Magnetic resonance imaging
KW - Non-Gaussian diffusion
KW - Statistical model
UR - http://www.scopus.com/inward/record.url?scp=84976869596&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84976869596&partnerID=8YFLogxK
U2 - 10.2463/mrms.mp.2015-0067
DO - 10.2463/mrms.mp.2015-0067
M3 - Article
C2 - 26701694
AN - SCOPUS:84976869596
SN - 1347-3182
VL - 15
SP - 237
EP - 245
JO - Magnetic Resonance in Medical Sciences
JF - Magnetic Resonance in Medical Sciences
IS - 2
ER -