Flow immunophenotyping of benign lymph nodes sampled by FNA: Representative with diagnostic pitfalls

Gregory D. Scott, Hubert D. Lau, Jason H. Kurzer, Christina S. Kong, Dita A. Gratzinger

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Background: Fine-needle aspiration with flow cytometry (FNA-FC) is routinely used in the evaluation of lymph nodes suspicious for lymphoma, yet data comparing immunophenotype distributions and outliers in benign lymph nodes sampled by fine-needle aspiration (FNA) versus excision are lacking. Methods: Flow cytometry data from 289 benign lymph node FNA cases were assessed for the overall antigen distribution, with a focus on outliers relevant to the diagnosis of lymphoma. Distributions and outlier proportions were compared with those of a separate cohort of 298 excisional biopsies. Results: Compared with excisional biopsies, FNA specimens overrepresented CD3+ events (72% vs 63%), underrepresented CD19+ events (22% vs 29%), and had 25% fewer large cell–gated events. Normalized antigen distributions in FNA were equivalent to those in excisional biopsy. Twenty-three percent of FNA-FC cases exhibited an outlier, including a skewed kappa:lambda light-chain ratio, increased CD5+ or CD10+ B-cell events, a skewed CD4:CD8 ratio, and increased CD7 loss on T cells, with no significant differences in frequency or type in comparison with excisional specimens. Outliers for the light-chain ratio and T-cell antigens were enriched among older patients and included patients with a variety of autoimmune/rheumatologic conditions. Conclusions: Benign lymph node FNA yields flow immunophenotypes remarkably similar to those from excisional biopsies. Outlier flow immunophenotypes are identified in benign lymph nodes sampled by FNA at a frequency similar to that with excisional biopsies. Older patients, who have a higher baseline risk of lymphoma, are more likely to exhibit lymphoma-mimicking outliers such as a light-chain predominance on B cells and skewed CD4:CD8 ratios or increased CD7 loss on T cells, and they warrant additional diagnostic caution.

Original languageEnglish (US)
Pages (from-to)797-808
Number of pages12
JournalCancer Cytopathology
Volume126
Issue number9
DOIs
StatePublished - Sep 2018
Externally publishedYes

Keywords

  • cytometry
  • distribution
  • flow
  • immunophenotype
  • informatics
  • lymph node
  • outlier

ASJC Scopus subject areas

  • Oncology
  • Cancer Research

Fingerprint

Dive into the research topics of 'Flow immunophenotyping of benign lymph nodes sampled by FNA: Representative with diagnostic pitfalls'. Together they form a unique fingerprint.

Cite this