N2 - Two methods of transmission Fourier Transform Infrared analysis were compared to determine the degree of polymerization (DP) in unfilled Bis-GMA-based dental resins. Diluent concentration, curing mode, and activator type were investigated. DP ranged from 55-72% and was highest for the most diluted resins. The effects of polymerization activation mode and type were insignificant. DP was slightly enhanced in the bulk of the resin, as determined by a KBr-pellet technique, in comparison with results from a thin film method, but both techniques seem to provide useful and reproducible results for dental resins.
AB - Two methods of transmission Fourier Transform Infrared analysis were compared to determine the degree of polymerization (DP) in unfilled Bis-GMA-based dental resins. Diluent concentration, curing mode, and activator type were investigated. DP ranged from 55-72% and was highest for the most diluted resins. The effects of polymerization activation mode and type were insignificant. DP was slightly enhanced in the bulk of the resin, as determined by a KBr-pellet technique, in comparison with results from a thin film method, but both techniques seem to provide useful and reproducible results for dental resins.
UR - http://www.scopus.com/inward/record.url?scp=0021478016&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0021478016&partnerID=8YFLogxK
U2 - 10.1177/00220345840630081901
DO - 10.1177/00220345840630081901
M3 - Article
C2 - 6235253
AN - SCOPUS:0021478016
SN - 0022-0345
VL - 63
SP - 1093
EP - 1095
JO - Journal of Dental Research
JF - Journal of Dental Research
IS - 8
ER -