TY - JOUR
T1 - Multicenter assessment of augmented reality registration methods for image-guided interventions
AU - Li, Ningcheng
AU - Wakim, Jonathan
AU - Koethe, Yilun
AU - Huber, Timothy
AU - Schenning, Ryan
AU - Gade, Terence P.
AU - Hunt, Stephen J.
AU - Park, Brian J.
N1 - Publisher Copyright:
© 2022, Italian Society of Medical Radiology.
PY - 2022/8
Y1 - 2022/8
N2 - Purpose: To evaluate manual and automatic registration times and registration accuracies on HoloLens 2 for aligning a 3D CT phantom model onto a CT grid, a crucial step for intuitive 3D navigation during CT-guided interventions; to compare registration times between HoloLens 1 and 2. Methods: Eighteen participants in various stages of clinical training across two academic centers performed registration of a 3D CT phantom model onto a CT grid using HoloLens 2. Registration times and accuracies were compared among different registration methods, clinical experience levels, and consecutive attempts. Registration times were also compared retrospectively to prior HoloLens 1 results. Results: Mean aggregate manual registration times were 27.7 s, 24.3 s, and 72.8 s for one-handed gesture, two-handed gesture, and Xbox controller, respectively; mean automatic registration time was 5.3 s (ANOVA p < 0.0001). No significant difference in registration times was found among attendings, residents and fellows, and medical students (p > 0.05). Significant improvements in registration times were detected across consecutive attempts using hand gestures (p < 0.01). Compared to prior HoloLens 1 data, hand gesture registration was 81.7% faster with HoloLens 2 (p < 0.05). Registration accuracies were not significantly different across manual registration methods, measuring at 5.9 mm, 9.5 mm, and 8.6 mm with one-handed gesture, two-handed gesture, and Xbox controller, respectively (p > 0.05). Conclusions: Manual registration times decreased significantly on HoloLens 2, approaching those of automatic registration and outperforming Xbox controller registration. Fast, adaptive, and accurate registration of holographic models of cross-sectional imaging is paramount for the implementation of augmented reality-assisted 3D navigation during CT-guided interventions.
AB - Purpose: To evaluate manual and automatic registration times and registration accuracies on HoloLens 2 for aligning a 3D CT phantom model onto a CT grid, a crucial step for intuitive 3D navigation during CT-guided interventions; to compare registration times between HoloLens 1 and 2. Methods: Eighteen participants in various stages of clinical training across two academic centers performed registration of a 3D CT phantom model onto a CT grid using HoloLens 2. Registration times and accuracies were compared among different registration methods, clinical experience levels, and consecutive attempts. Registration times were also compared retrospectively to prior HoloLens 1 results. Results: Mean aggregate manual registration times were 27.7 s, 24.3 s, and 72.8 s for one-handed gesture, two-handed gesture, and Xbox controller, respectively; mean automatic registration time was 5.3 s (ANOVA p < 0.0001). No significant difference in registration times was found among attendings, residents and fellows, and medical students (p > 0.05). Significant improvements in registration times were detected across consecutive attempts using hand gestures (p < 0.01). Compared to prior HoloLens 1 data, hand gesture registration was 81.7% faster with HoloLens 2 (p < 0.05). Registration accuracies were not significantly different across manual registration methods, measuring at 5.9 mm, 9.5 mm, and 8.6 mm with one-handed gesture, two-handed gesture, and Xbox controller, respectively (p > 0.05). Conclusions: Manual registration times decreased significantly on HoloLens 2, approaching those of automatic registration and outperforming Xbox controller registration. Fast, adaptive, and accurate registration of holographic models of cross-sectional imaging is paramount for the implementation of augmented reality-assisted 3D navigation during CT-guided interventions.
KW - 3D visualization
KW - Augmented reality
KW - CT-guided intervention
KW - HoloLens
KW - Interventional radiology
KW - Mixed reality
KW - Registration
UR - http://www.scopus.com/inward/record.url?scp=85132580113&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85132580113&partnerID=8YFLogxK
U2 - 10.1007/s11547-022-01515-3
DO - 10.1007/s11547-022-01515-3
M3 - Article
C2 - 35737194
AN - SCOPUS:85132580113
SN - 0033-8362
VL - 127
SP - 857
EP - 865
JO - Radiologia Medica
JF - Radiologia Medica
IS - 8
ER -