TY - JOUR
T1 - Non-invasive Evaluation of Right Ventricular Function with Real-Time 3-D Echocardiography
AU - Chen, Ran
AU - Zhu, Meihua
AU - Amacher, Kacie
AU - Wu, Xia
AU - Sahn, David J.
AU - Ashraf, Muhammad
N1 - Funding Information:
The study was financially supported by the Natural Science Foundation of Zhejiang Province, China (Grant LQ14 H180002) and the National Natural Science Foundation of China (Grant 81401493)
Publisher Copyright:
© 2017 World Federation for Ultrasound in Medicine & Biology
PY - 2017/10
Y1 - 2017/10
N2 - The aim of this study was to evaluate the accuracy and feasibility of real-time 3-D echocardiography (3-DE) in assessing right ventricular (RV) systolic function. A latex balloon was inserted into the right ventricle of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. The RV global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and RV ejection fraction (RVEF), derived from 3-DE, as well as the RVEF obtained from 2-D echocardiography (2-DE) were quantified at different stroke volumes (30–70 mL) and compared with sonomicrometry data. In all comparisons, 3-D GLS, GCS, GAS, 2-D RVEF and 3-D RVEF exhibited strong correlations with sonomicrometry data (r = 0.89, 0.79, 0.74, 0.80, and 0.93, respectively; all p values < 0.001). Bland–Altman analyses revealed slight overestimations of echo-derived GLS, GCS, 2-DE RVEF and 3-DE RVEF compared with sonomicrometry values (bias = 1.55, 2.72, 3.59 and 2.21, respectively). Furthermore, there is better agreement among GLS, 3-D RVEF and the sonomicrometry values than between GCS and 2-D RVEF. Real-time 3-DE is more feasible and accurate for assessing RV function than 2-DE. GLS is a potential alternative parameter for quantifying RV systolic function.
AB - The aim of this study was to evaluate the accuracy and feasibility of real-time 3-D echocardiography (3-DE) in assessing right ventricular (RV) systolic function. A latex balloon was inserted into the right ventricle of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. The RV global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and RV ejection fraction (RVEF), derived from 3-DE, as well as the RVEF obtained from 2-D echocardiography (2-DE) were quantified at different stroke volumes (30–70 mL) and compared with sonomicrometry data. In all comparisons, 3-D GLS, GCS, GAS, 2-D RVEF and 3-D RVEF exhibited strong correlations with sonomicrometry data (r = 0.89, 0.79, 0.74, 0.80, and 0.93, respectively; all p values < 0.001). Bland–Altman analyses revealed slight overestimations of echo-derived GLS, GCS, 2-DE RVEF and 3-DE RVEF compared with sonomicrometry values (bias = 1.55, 2.72, 3.59 and 2.21, respectively). Furthermore, there is better agreement among GLS, 3-D RVEF and the sonomicrometry values than between GCS and 2-D RVEF. Real-time 3-DE is more feasible and accurate for assessing RV function than 2-DE. GLS is a potential alternative parameter for quantifying RV systolic function.
KW - Global strain
KW - Real-time 3-D echocardiography
KW - Right ventricular function
UR - http://www.scopus.com/inward/record.url?scp=85023600826&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85023600826&partnerID=8YFLogxK
U2 - 10.1016/j.ultrasmedbio.2017.05.007
DO - 10.1016/j.ultrasmedbio.2017.05.007
M3 - Article
C2 - 28716430
AN - SCOPUS:85023600826
SN - 0301-5629
VL - 43
SP - 2247
EP - 2255
JO - Ultrasound in Medicine and Biology
JF - Ultrasound in Medicine and Biology
IS - 10
ER -