TY - JOUR
T1 - Non-mydriatic single-field fundus photography for the screening of retinal diseases in an executive health clinic
AU - Tarabishy, Ahmad B.
AU - Campbell, John P.
AU - Misra-Hebert, Anita
AU - Seballos, Raul J.
AU - Lang, Richard S.
AU - Singh, Rishi P.
PY - 2011/3
Y1 - 2011/3
N2 - ■ BACKGROUND AND OBJECTIVE: To determine the accuracy and sensitivity of a single-field non-mydriatic digital fundus image interpreted by an ophthalmologist and performed within a primary care setting. ■ PATIENTS AND METHODS: Fundus photography using a digital non-mydriatic camera was performed on both eyes of 1,175 consecutive patients as part of an executive health program. All fundus images included a 45° field of the posterior pole capturing the optic nerve and macular area. Diagnostic findings were recorded and appropriate recommendations for follow- up were made. Patients were then contacted to see whether appropriate follow-up was successfully completed and chart reviews were performed to determine biomicroscopic findings. ■ RESULTS: Photographs were adequate in both eyes in 1,117 patients (95.1%). Examination findings were normal in both eyes in 951 (85.1%) patients. Abnormal findings were noted in either eye in 166 (14.9%) patients. The most common abnormal findings were macular degeneration (57/166, 34.3%), optic nerve cupping (45/166, 27.1%), hypertensive retinopathy (15/166, 9.0%), and choroidal nevi (10/166, 6.0%). In all patients with abnormal findings, routine follow-up ophthalmologic examination with an eye care specialist was indicated and none of the patients required urgent attention. Sensitivity was found to be 87% and stratification was performed based on the initial diagnosis. False-positive results were from confounding diagnoses rather than true false-positives. ■ CONCLUSION: Single-field non-mydriatic fundus photography is accurate and sensitive for screening retinal disease in a primary care setting.
AB - ■ BACKGROUND AND OBJECTIVE: To determine the accuracy and sensitivity of a single-field non-mydriatic digital fundus image interpreted by an ophthalmologist and performed within a primary care setting. ■ PATIENTS AND METHODS: Fundus photography using a digital non-mydriatic camera was performed on both eyes of 1,175 consecutive patients as part of an executive health program. All fundus images included a 45° field of the posterior pole capturing the optic nerve and macular area. Diagnostic findings were recorded and appropriate recommendations for follow- up were made. Patients were then contacted to see whether appropriate follow-up was successfully completed and chart reviews were performed to determine biomicroscopic findings. ■ RESULTS: Photographs were adequate in both eyes in 1,117 patients (95.1%). Examination findings were normal in both eyes in 951 (85.1%) patients. Abnormal findings were noted in either eye in 166 (14.9%) patients. The most common abnormal findings were macular degeneration (57/166, 34.3%), optic nerve cupping (45/166, 27.1%), hypertensive retinopathy (15/166, 9.0%), and choroidal nevi (10/166, 6.0%). In all patients with abnormal findings, routine follow-up ophthalmologic examination with an eye care specialist was indicated and none of the patients required urgent attention. Sensitivity was found to be 87% and stratification was performed based on the initial diagnosis. False-positive results were from confounding diagnoses rather than true false-positives. ■ CONCLUSION: Single-field non-mydriatic fundus photography is accurate and sensitive for screening retinal disease in a primary care setting.
UR - http://www.scopus.com/inward/record.url?scp=79958121852&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79958121852&partnerID=8YFLogxK
U2 - 10.3928/15428877-20110316-01
DO - 10.3928/15428877-20110316-01
M3 - Article
C2 - 21410106
AN - SCOPUS:79958121852
SN - 2325-8160
VL - 42
SP - 102
EP - 106
JO - Ophthalmic Surgery and Lasers
JF - Ophthalmic Surgery and Lasers
IS - 2
ER -