T1 - Parallel reaction monitoring (PRM) and selected reaction monitoring (SRM) exhibit comparable linearity, dynamic range and precision for targeted quantitative HDL proteomics
AU - Ronsein, Graziella E.
AU - Pamir, Nathalie
AU - von Haller, Priska D.
AU - Kim, Daniel S.
AU - Oda, Michael N.
AU - Jarvik, Gail P.
AU - Vaisar, Tomas
AU - Heinecke, Jay W.
N1 - Funding Information:
Mass spectrometry experiments were performed in the University of Washington's Proteomics Resource (UWPR95794) and the Quantitative and the Functional Proteomics Core of the Diabetes Research Center, University of Washington (DK017047). This work was supported by grants from the American Heart Association ( 14POST18620020 ) and the National Institutes of Health ( HL086798 , HL091055 , HL092969 , HL108897 , HL112625 ). None of the sponsors had any role in study design, data analysis, or reporting of the results.
Publisher Copyright:
© 2014 Elsevier B.V.
PY - 2015/1/5
Y1 - 2015/1/5
N2 - High-density lipoprotein (HDL), a lipid nanoparticle containing many different low abundance proteins, is an attractive target for clinical proteomics because its compositional heterogeneity is linked to its cardioprotective effects. Selected reaction monitoring (SRM) is currently the method of choice for targeted quantification of proteins in such a complex biological matrix. However, model system studies suggest that parallel reaction monitoring (PRM) is more specific than SRM because many product ions can be used to confirm the identity of a peptide. We therefore compared PRM and SRM for their abilities to quantify proteins in HDL, using 15N-labeled apolipoprotein A-I (HDL's most abundant protein) as the internal standard. PRM and SRM exhibited comparable linearity, dynamic range, precision, and repeatability for protein quantification of HDL. Moreover, the single internal standard protein performed as well as protein-specific peptide internal standards when quantifying 3 different proteins. Importantly, PRM and SRM yielded virtually identical quantitative results for 26 proteins in HDL isolated from 44 subjects. Because PRM requires less method development than SRM and is potentially more specific, our observations indicate that PRM in concert with a single isotope-labeled protein is a promising new strategy for quantifying HDL proteins in translational studies. Biological significance: HDL, a complex matrix composed of lipids and proteins, is implicated in cardioprotection. Its cholesterol content correlates inversely with cardiovascular disease and it is the current metric to assess cardiovascular risk. However, the cholesterol content does not capture HDL's complexity and heterogeneity. Devising metrics that better capture HDL's cardioprotective effects, we developed an optimized method for quantification of HDL proteome, using PRM in concert with a single labeled protein as internal standard. The availability of a method that increases sample throughput without compromising the reproducibility, sensitivity, and accuracy could therefore point to better risk assessment for CVD or other diseases.
AB - High-density lipoprotein (HDL), a lipid nanoparticle containing many different low abundance proteins, is an attractive target for clinical proteomics because its compositional heterogeneity is linked to its cardioprotective effects. Selected reaction monitoring (SRM) is currently the method of choice for targeted quantification of proteins in such a complex biological matrix. However, model system studies suggest that parallel reaction monitoring (PRM) is more specific than SRM because many product ions can be used to confirm the identity of a peptide. We therefore compared PRM and SRM for their abilities to quantify proteins in HDL, using 15N-labeled apolipoprotein A-I (HDL's most abundant protein) as the internal standard. PRM and SRM exhibited comparable linearity, dynamic range, precision, and repeatability for protein quantification of HDL. Moreover, the single internal standard protein performed as well as protein-specific peptide internal standards when quantifying 3 different proteins. Importantly, PRM and SRM yielded virtually identical quantitative results for 26 proteins in HDL isolated from 44 subjects. Because PRM requires less method development than SRM and is potentially more specific, our observations indicate that PRM in concert with a single isotope-labeled protein is a promising new strategy for quantifying HDL proteins in translational studies. Biological significance: HDL, a complex matrix composed of lipids and proteins, is implicated in cardioprotection. Its cholesterol content correlates inversely with cardiovascular disease and it is the current metric to assess cardiovascular risk. However, the cholesterol content does not capture HDL's complexity and heterogeneity. Devising metrics that better capture HDL's cardioprotective effects, we developed an optimized method for quantification of HDL proteome, using PRM in concert with a single labeled protein as internal standard. The availability of a method that increases sample throughput without compromising the reproducibility, sensitivity, and accuracy could therefore point to better risk assessment for CVD or other diseases.
KW - HDL
KW - PRM
KW - SRM
KW - Single internal standard protein
KW - Targeted proteomics
UR - http://www.scopus.com/inward/record.url?scp=84909953587&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84909953587&partnerID=8YFLogxK
U2 - 10.1016/j.jprot.2014.10.017
DO - 10.1016/j.jprot.2014.10.017
M3 - Article
C2 - 25449833
AN - SCOPUS:84909953587
SN - 1874-3919
VL - 113
SP - 388
EP - 399
JO - Journal of Proteomics
JF - Journal of Proteomics