Performance of a novel protease-activated fluorescent imaging system for intraoperative detection of residual breast cancer during breast conserving surgery

Conor R. Lanahan, Bridget N. Kelly, Michele A. Gadd, Michelle C. Specht, Carson L. Brown, Kevin S. Hughes, Rong Tang, Upahvan Rai, Elena F. Brachtel, Travis Rice-Stitt, Barbara L. Smith

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Purpose: Safe breast cancer lumpectomies require microscopically clear margins. Real-time margin assessment options are limited, and 20–40% of lumpectomies have positive margins requiring re-excision. The LUM Imaging System previously showed excellent sensitivity and specificity for tumor detection during lumpectomy surgery. We explored its impact on surgical workflow and performance across patient and tumor types. Methods: We performed IRB-approved, prospective, non-randomized studies in breast cancer lumpectomy procedures. The LUM Imaging System uses LUM015, a protease-activated fluorescent imaging agent that identifies residual tumor in the surgical cavity walls. Fluorescent cavity images were collected in real-time and analyzed using system software. Results: Cavity and specimen images were obtained in 55 patients injected with LUM015 at 0.5 or 1.0 mg/kg and in 5 patients who did not receive LUM015. All tumor types were distinguished from normal tissue, with mean tumor:normal (T:N) signal ratios of 3.81–5.69. T:N ratios were 4.45 in non-dense and 4.00 in dense breasts (p = 0.59) and 3.52 in premenopausal and 4.59 in postmenopausal women (p = 0.19). Histopathology and tumor receptor testing were not affected by LUM015. Falsely positive readings were more likely when tumor was present < 2 mm from the adjacent specimen margin. LUM015 signal was stable in vivo at least 6.5 h post injection, and ex vivo at least 4 h post excision. Conclusions: Intraoperative use of the LUM Imaging System detected all breast cancer subtypes with robust performance independent of menopausal status and breast density. There was no significant impact on histopathology or receptor evaluation.

Original languageEnglish (US)
Pages (from-to)145-153
Number of pages9
JournalBreast Cancer Research and Treatment
Volume187
Issue number1
DOIs
StatePublished - May 2021
Externally publishedYes

Keywords

  • Image-guided surgery
  • Intraoperative tumor detection
  • Lumpectomy
  • Margin assessment