Risk of reverse golf club deformity with medial plating of distal femur fracture

Tyler J. Thorne, Graham J. DeKeyser, Ian Clapp, Justin M. Haller

Research output: Contribution to journalArticlepeer-review

Abstract

Introduction: This study described a deformity induced by medial plating of supracondylar distal femur fractures using plates that are precontoured for other anatomic locations. Materials and methods: OTA/AO 33A fractures were created in 12 sawbone femurs and fixed with either a proximal humerus locking plate (PH), an ipsilateral lateral tibial plateau plate (LTP), or an ipsilateral medial distal tibial plate (MDT). A motion capture system measured changes in length and rotation of the distal femur as the plate was applied. Each plate underwent four trials and the mean and standard deviation (SD) for each measurement was reported. An analysis of variance with post hoc Tukey test compared malreduction measures between plate types. Results: All plates consistently created a varus deformity. There was lateral lengthening with a compensatory medial shortening and an increase in the lateral distal femoral angle. The distal fracture fragment was laterally translated, and internally rotated. The PH plate had significantly greater lateral length (27.39 mm SD 4.78, p = 0.007), shorter medial length (13.57 mm SD 4.99, p = 0.028), greater lateral translation (28.82 mm SD 5.70, p = 0.010) and greater widening of the lateral distal femoral angle (28.54° SD 4.98, p < 0.001) than the LTP and MDT plates. The MDT plate had significantly greater angulation anteriorly (8.40° SD 1.07, p < 0.001) and laterally (7.63° SD 3.10, p = 0.002) than the PH and LTP plates. There was no significant difference between plates in internal rotation (PH: 3.07° SD 2.79; LTP: 2.05° SD 1.05; MDT 3.81° SD 3.56; p = 0.659). Conclusion: When dual plating supracondylar distal femur fractures, poor plate positioning and a mismatch between plate contour and the slope of the medial distal femur can lead to varus angulation, internal rotation, and lateral translation or a “reverse golf club deformity”. After comparing three types of precontoured plates, the authors recommend initial evaluation of the ipsilateral proximal tibial plate when placing a plate along the medial distal femur. Level of evidence: IV.

Original languageEnglish (US)
Pages (from-to)1211-1220
Number of pages10
JournalArchives of Orthopaedic and Trauma Surgery
Volume144
Issue number3
DOIs
StatePublished - Mar 2024

Keywords

  • Deformity
  • Distal femur
  • Dual plating
  • Malreduction
  • Malunion
  • Medial plating
  • Trauma

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Risk of reverse golf club deformity with medial plating of distal femur fracture'. Together they form a unique fingerprint.

Cite this