TY - JOUR
T1 - Time-Driven Activity-Based Costing Comparison of Stereotactic Radiosurgery to Multiple Brain Lesions Using Single-Isocenter Versus Multiple-Isocenter Technique
AU - Parikh, Neil R.
AU - Kundu, Palak
AU - Levin-Epstein, Rebecca
AU - Chang, Eric M.
AU - Agazaryan, Nzhde
AU - Hegde, John V.
AU - Steinberg, Michael L.
AU - Tenn, Stephen E.
AU - Kaprealian, Tania B.
N1 - Funding Information:
Disclosures: N.A. reports grants and personal fees from Brainlab. J.V.H. reports nonfinancial support from Soylent Nutrition, Inc. M.L.S. reports personal fees from ViewRay and from Vision RT. S.T. reports previously receiving personal fees from Brainlab (ended in 2018).
Publisher Copyright:
© 2020 Elsevier Inc.
PY - 2020/11/15
Y1 - 2020/11/15
N2 - Purpose: Stereotactic radiosurgery (SRS) historically has been used to treat multiple brain lesions using a multiple-isocenter technique—frequently associated with significant complexity in treatment planning and long treatment times. Recently, given innovations in planning algorithms, patients with multiple brain lesions may now be treated with a single-isocenter technique using fewer total arcs and less time spent during image guidance (though with stricter image guided radiation therapy tolerances). This study used time-driven activity-based costing to determine the difference in cost to a provider for delivering SRS to multiple brain lesions using single-isocenter versus multiple-isocenter techniques. Methods and Materials: Process maps, consisting of discrete steps, were created for each phase of the SRS care cycle and were based on interviews with department personnel. Actual treatment times (including image guidance) were extracted from treatment record and verify software. Additional sources of data to determine costs included salary/benefit data of personnel and average list price/maintenance costs for equipment. Results: Data were collected for 22 patients who underwent single-isocenter SRS (mean lesions treated, 5.2; mean treatment time, 30.2 minutes) and 51 patients who underwent multiple-isocenter SRS (mean lesions treated, 4.4; mean treatment time, 75.2 minutes). Treatment time for multiple-isocenter SRS varied substantially with increasing number of lesions (11.8 minutes/lesion; P < .001), but to a much lesser degree in single-isocenter SRS (1.8 minutes/lesion; P = .029). The resulting cost savings from single-isocenter SRS based on number of lesions treated ranged from $296 to $3878 for 2 to 10 lesions treated. The 2-mm planning treatment volume margin used with single-isocenter SRS resulted in a mean 43% increase of total volume treated compared with a 1-mm planning treatment volume expansion. Conclusions: In a comparison of time-driven activity-based costing assessment of single-isocenter versus multiple-isocenter SRS for multiple brain lesions, single-isocenter SRS appears to save time and resources for as few as 2 lesions, with incremental benefits for additional lesions treated.
AB - Purpose: Stereotactic radiosurgery (SRS) historically has been used to treat multiple brain lesions using a multiple-isocenter technique—frequently associated with significant complexity in treatment planning and long treatment times. Recently, given innovations in planning algorithms, patients with multiple brain lesions may now be treated with a single-isocenter technique using fewer total arcs and less time spent during image guidance (though with stricter image guided radiation therapy tolerances). This study used time-driven activity-based costing to determine the difference in cost to a provider for delivering SRS to multiple brain lesions using single-isocenter versus multiple-isocenter techniques. Methods and Materials: Process maps, consisting of discrete steps, were created for each phase of the SRS care cycle and were based on interviews with department personnel. Actual treatment times (including image guidance) were extracted from treatment record and verify software. Additional sources of data to determine costs included salary/benefit data of personnel and average list price/maintenance costs for equipment. Results: Data were collected for 22 patients who underwent single-isocenter SRS (mean lesions treated, 5.2; mean treatment time, 30.2 minutes) and 51 patients who underwent multiple-isocenter SRS (mean lesions treated, 4.4; mean treatment time, 75.2 minutes). Treatment time for multiple-isocenter SRS varied substantially with increasing number of lesions (11.8 minutes/lesion; P < .001), but to a much lesser degree in single-isocenter SRS (1.8 minutes/lesion; P = .029). The resulting cost savings from single-isocenter SRS based on number of lesions treated ranged from $296 to $3878 for 2 to 10 lesions treated. The 2-mm planning treatment volume margin used with single-isocenter SRS resulted in a mean 43% increase of total volume treated compared with a 1-mm planning treatment volume expansion. Conclusions: In a comparison of time-driven activity-based costing assessment of single-isocenter versus multiple-isocenter SRS for multiple brain lesions, single-isocenter SRS appears to save time and resources for as few as 2 lesions, with incremental benefits for additional lesions treated.
UR - http://www.scopus.com/inward/record.url?scp=85089596206&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85089596206&partnerID=8YFLogxK
U2 - 10.1016/j.ijrobp.2020.06.035
DO - 10.1016/j.ijrobp.2020.06.035
M3 - Article
C2 - 32603774
AN - SCOPUS:85089596206
SN - 0360-3016
VL - 108
SP - 999
EP - 1007
JO - International Journal of Radiation Oncology Biology Physics
JF - International Journal of Radiation Oncology Biology Physics
IS - 4
ER -